This air-cooled condensing reference
Request the matched evaporating equipment and the intended refrigerant-system boundary. Obtain the supplier’s coordinated selection rather than assuming compatibility from capacity labels alone.
Read the sourceA ship/offshore catalogue reference with no published model schedule: define the matched system and request performance at the vessel’s design conditions.
From Jiangsu Yongsheng Air Conditioning Co., Ltd.
Individual product research · HVACDeck Editorial · Sources checked 2026-10-11
Yongsheng’s official listing calls this product 风冷压缩冷凝机组—an air-cooled compressor-condensing assembly—and places it under central air-conditioning systems for ships and offshore engineering. It was published on 5 November 2022. The reviewed page supplies a product photo and a request-for-information prompt, but its parameters area contains no readable rating or model table.
This is a family reference, not a specification for a particular unit. The name and category are enough to frame an enquiry; they are insufficient to choose cooling capacity, refrigerant, power supply, compressor configuration or class approval. Obtain an identified model and matched-system schedule before comparison with another bid.
The page links water-cooled assembled air conditioners and chilled-water equipment as related products. Those links describe alternatives in the manufacturer’s portfolio, not components or performance values included in this assembly.
This is an equipment family; its range does not identify one orderable configuration.
Swipe the table, or focus it and use arrow keys, to read the conditions and sources.
| Parameter | Published value | Conditions and evidence |
|---|---|---|
| Official product name | 风冷压缩冷凝机组 | Air-cooled compressor-condensing assembly; no individual model designation established. Source |
| Catalogue context | Ship and offshore central air-conditioning systems | Official classification, not evidence of approval for a particular vessel or hazardous area. Source |
| Publication date | 5 November 2022 | Listing date; it does not identify a current design revision. Source |
| Selection-table status | No readable model/rating schedule on reviewed page | Capacity, refrigerant, power and operating limits must be requested for the proposed unit. Source |
The original listing names the air-cooled assembly and provides a main image of an enclosed unit with a large grille and an instrument/control area. The image was visually reviewed. It has no readable model nameplate or rating table from which to establish duty or electrical demand. It cannot confirm casing material, corrosion protection, refrigerant, compressor count or internal piping.
The brief description includes broad tags for marine, industrial, military, mining and special-purpose air conditioning. Treat these as catalogue wording. They do not demonstrate that one quoted configuration meets every environment or approval regime.
A condensing assembly enquiry must name the connected equipment and the interface responsibility. The public listing does not define whether matching equipment, refrigerant piping, controls or installation services are included. The following distinctions help prevent a category-level comparison from becoming an incompatible order.
Request the matched evaporating equipment and the intended refrigerant-system boundary. Obtain the supplier’s coordinated selection rather than assuming compatibility from capacity labels alone.
Read the sourceA separately linked catalogue item. Obtain its own cooling-water and system schedule if the project selects that arrangement; this page supplies none of its ratings.
Read the sourceRelated air-cooled and water-cooled water units belong to a different catalogue arrangement. Their hydraulic specifications cannot be attributed to this compressor-condensing listing.
Read the sourceNeither nominal kW nor electrical input is published in the readable listing. Ask each bidder to state the same design conditions and the delivered scope, so an attractive catalogue headline does not hide a mismatch in operating point. These are requested selection documents, not capabilities verified for this family.
Request model/revision, refrigerant, matched equipment, cooling output and input at the agreed ambient and evaporating-side conditions, with the rating method and allowable operating envelope.
Request general arrangement, dimensions, operating weight, connection details, service clearances, airflow requirements and the proposed piping/control boundary.
Request supply and tolerances, starting/current data, protection and isolating requirements, control interfaces and a versioned wiring schedule. No power rating can be taken from the product photograph.
The company overview lists multiple classification societies and certification systems across its business. It does not identify a current certificate number or covered model schedule for this air-cooled condensing reference. No unit-specific class or explosion-protection approval was verified by this review.
For the quoted unit, reconcile the manufacturer/site, model, approval scope and conditions with the vessel’s requirements. Agree which project-specific inspection, witness points, tests and certificates will be delivered. If a hazardous location is involved, obtain its exact required marking and certificate scope separately; marine use alone does not establish suitability.
The responsible vessel/yard design team identifies the applicable class, installation conditions and required documents.
Check the quoted model and revision against the current certificate schedule and any exclusions. Ask for unresolved gaps before contract award.
Agree drawing approval, inspection/test plan, project certificates, manuals, commissioning records and sign-off responsibilities.
For a replacement, provide the existing unit nameplate, matched evaporating equipment, refrigerant, control/wiring documents, installation dimensions and operating history. A photograph and approximate capacity are not enough to establish compatibility. Ask the supplier to identify what can be reused, what must change and who approves the resulting system.
For a new installation, provide design loads and environmental constraints before asking for a model. Confirm access for installation and service, spare parts and support at the actual project location. The company contact page distinguishes overseas sales, but it does not provide a port-specific service guarantee.
The reviewed source leaves the model schedule, performance curves, refrigerant, electrical details, control interfaces, materials and current approvals open. That does not mean the supplier cannot provide them; the catalogue is simply insufficient for an engineering release.
The useful next deliverable is a dated technical offer with an identified unit, matched-system drawing, selection calculation, applicable approval evidence and acceptance/support scope. The associated factory review explains the exact company identity and why corporate recognition should be kept separate from product approval.
Compiled by HVACDeck Editorial. Source review identifies what the publication states; it is not an independent performance test or certification.
Editorial method and corrections · Report a detail with this page URL
Send the manufacturer your required duty, installation conditions and the unresolved items identified in this brief.