MANUFACTURER / SOURCE REVIEW

Heqiang · polyethylene insulation and installation accessories

Guangzhou Heqiang HVAC Materials Co., Ltd.

A Guangzhou supplier of PEF sheets, tubes, foil-faced and adhesive-backed forms; qualify the exact material build-up and installation system.

广州市, 广东省, China

Prepare a technical enquiry
1 published equipment referenceLatest source review 2026-10-11
01 / COMPANY

What this manufacturer offers

广州合强暖通空调材料有限公司 describes itself as a producer developing and selling polyethylene and composite aluminium-foil insulation materials and supporting products. The official contact page gives Yongan Road, Zhaidong Village, Yonghe, Xintang, Zengcheng, Guangzhou.

The catalogue separates PEF insulation, PE support blocks, sealing tapes, foil-faced sheets, insulation tubes and adhesive-backed sheets. These are different supply forms and interfaces. A supplier suitable for a chilled-water tube enquiry is not automatically qualified for every duct facing, support detail or project fire requirement.

The reviewed PEF item is image-led. A separate 2015 article publishes general figures, and an original 2023 patent publication identifies Heqiang for a particular flame-retardant formulation/process. Neither establishes the rating or composition of the current pictured rolls. This review keeps those scopes distinct.

Official company
广州合强暖通空调材料有限公司Official company/contact pages; exact entity also appears in the original patent grant publication. Source
Published contact location
Yongan Road, Zhaidong Village, Yonghe, Xintang, Zengcheng, GuangzhouOfficial contact address; no on-site manufacturing audit or current spare-capacity measurement. Source
Catalogue forms
PEF sheets/tubes · foil and adhesive-backed forms · support blocks · sealing tapesForms listed by the supplier; selected grade, thickness and accessory compatibility need written confirmation. Source
Original invention publication
CN115353681B · grant published 29 December 2023Names Heqiang and a material/preparation method; not a current finished-product fire or thermal certificate. Source
02 / EQUIPMENT

Published equipment and selection evidence

PEF polyethylene HVAC insulation catalogue family
series REFERENCE

PEF polyethylene HVAC insulation catalogue family

Catalogue reference: PEF insulation family

Open the equipment selection brief
Parameters and source limits · PEF insulation family

Swipe the table, or focus it and use arrow keys, to read conditions and sources.

Manufacturer-published information · PEF insulation family
ParameterPublished valueConditions and evidence
Catalogue itemPEF insulation materials · item 632Listed 15 August 2024; photographed rolls, no readable grade/rating label. Source
Historical density20–30 kg/m³2015 adhesive-backed PEF article, not confirmed for item632 or its current offered grade. Source
Historical conductivity wording0.035 w/m.h.℃ as printedUnusual source unit; no test method/mean temperature. Not silently converted into a certified W/(m·K) value. Source
Temperature wording−50°C to 110°C, marked short-termHistorical article; continuous limits and adhesive/facing limits require current confirmation. Source
03 / PROJECT REVIEW

Evaluate Heqiang against an insulation schedule, not a generic foam description

Choose the procurement form before comparing offers

Heqiang’s catalogue is broader than a single roll of foam. For a duct project, identify flat insulation, its facing, the adhesive and joint tape. For pipework, state whether preformed tubing, cut sheet or a support-block detail is required. Specify whether accessories are included in the same system or separately sourced.

The supplier introduction says it uses foaming and further-processing equipment, but supplies no reviewed line schedule, capacity or tolerance matrix. Ask which production/converting process supplies the proposed form and how thickness, density, facing bond and dimensional tolerances are checked.

Sheets and duct insulation

Approve width/length/thickness, facing and seam details for the actual duct environment.

Pipe insulation and supports

Specify pipe outside diameter, tube fit, insulation thickness, fittings and compatible support details.

Adhesive/facing accessories

Identify backing adhesive, glue and tape products, their installation conditions and compatible surfaces.

Keep the 2015 figures attached to their historical article

The adhesive-backed-board article dated 27 March 2015 lists density 20–30 kg/m³, water absorption ≤1%, oxygen index ≥27 and a temperature expression of −50°C to 110°C marked short-term. Its conductivity text is printed as 0.035 w/m.h.℃, without a test method or mean temperature. It also contains interleaved tube-like and sheet-size entries.

Those figures are useful questions for a current technical data sheet; they are not an authenticated specification for catalogue item 632. Ask for the exact proposed grade and current methods/conditions, with tolerances and a report corresponding to its composition, facing and thickness. Do not silently normalise the unusual conductivity unit or turn the short-term temperature into continuous service.

Read the displayed patents as research evidence, not certification

The actual image under the official qualification page shows two framed utility-model patent certificates, not a thermal-conductivity or reaction-to-fire test report. Some small text is not sufficiently legible for reliable detailed identifiers; it is not transcribed by guessing.

Separately, original invention grant publication CN115353681B names Heqiang, application date 20 August 2022 and grant publication 29 December 2023. It describes a specific flame-retardant insulation formulation/preparation method and experimental examples. Its publication does not demonstrate that the photographed PEF stock uses that formulation, nor authenticate the current patent status or a project classification. Ask for current rights information only where relevant, and independently qualify the supplied material.

Official gallery image

Two utility-model certificate images; no current finished-material thermal/fire test established.

Read the source

Original invention publication

Named entity and historical grant publication for a formulation/process; no automatic transfer of example results to item 632.

Read the source

Treat marketing properties as test questions for one grade

The introduction promotes antibacterial, mould-resistant, antistatic and ageing-resistant properties and broad environmental benefits. The reviewed pages do not attach grade-specific reports, test organisms/conditions or emission evidence to the current PEF item.

If one property is essential, put the required test and acceptance into the enquiry and ask for a matching report. Distinguish the foam, backing adhesive and foil-faced finished system. Oxygen-index wording alone does not identify the project’s required complete reaction-to-fire classification, and a patent does not certify installation performance.

Installation and continuity matter alongside the foam material

The supplier’s 2015 installation article calls for joining/sealing cuts and joints with dedicated adhesive, staged installation of larger and smaller pipes, and sealing at pipe-insulation ends. It is a general historical guide and includes unclear wording about bonding width; it is not a complete selected-system installation specification.

Request current adhesive application, substrate preparation, seam/fitting, support and termination details. Agree how the contractor checks continuity at elbows, valves and supports. For cold service, ask for the selected thickness calculation and moisture-control details using actual fluid temperature and ambient humidity rather than assuming that any PEF thickness prevents condensation.

Assess delivery evidence and close the material-system offer

The reviewed case index repeats general engineering-case captions, while the environment index uses generic factory captions. They do not establish a named project’s selected grade, quantity, installation acceptance or monitored result. No fixed MOQ, price, delivery term or detailed warranty was verified.

Request a representative current production sample, lot identification, packing dimensions and the material/accessory data needed by the installer. Ask how changes in formulation, facing or adhesive are notified. For a project reference, obtain the specific supply and acceptance scope rather than treating a gallery as an endorsement.

  1. Freeze the insulation schedule

    Define service conditions, geometry, thickness calculation, facing and the required material/test scope.

  2. Approve the system sample

    Review foam/facing/adhesive and joint/support details, with current reports for the exact offered grade.

  3. Control delivery and installation

    Agree lot identification, tolerances, packaging, storage, application instructions and written defect-remedy terms.

07 / TRANSPARENCY

Sources and review scope

Compiled by HVACDeck Editorial. Page review: 2026-10-11. Publications are attributed below; their statements are not independent measurements by this platform.

  1. Official company introductionChecked 2026-10-11 · Actual text/category forms read; claimed special properties not authenticated grade-specific results.
  2. Official contactChecked 2026-10-11 · Actual address read; private CRM35 email/source fields already present, preserved.
  3. Official historical adhesive-backed PEF articleChecked 2026-10-11 · Actual 2015 text, unusual conductivity unit and interleaved geometry wording retained; not current item632 data.
  4. Official historical installation guidanceChecked 2026-10-11 · Actual 2015 guide read; no invented glue specification or unresolved width interpretation.
  5. Official qualification galleryChecked 2026-10-11 · Actual two-patent image visually read; not material certification.
  6. Original invention grant publication CN115353681BChecked 2026-10-11 · Original PDF downloaded/read: exact entity/date and formulation/experiment scope; no current legal status or catalogue-grade mapping inferred.
  7. Official engineering case indexChecked 2026-10-11 · Generic captions inspected; no grade-specific project acceptance claimed.
  8. Official PEF catalogue item632Checked 2026-10-11 · Actual description/photo read: rolled material with no named grade/rating schedule.