Jingxin · drawing-led duct fabrication in Mianyang

Sichuan Jingxin Ventilation Equipment Co., Ltd.

A local duct fabrication and installation supplier: clarify the contracting entity, material schedule and fabricated assembly before relying on production or application claims.

绵阳市, 四川省, China

Prepare a technical enquiry
1 published equipment referenceLatest source review 2026-10-11
01 / COMPANY

What this manufacturer offers

The current site identifies 四川精鑫通风设备有限公司 and a workshop contact at the Zaojiaopu building-materials market in Xinzao, Fucheng, Mianyang. Its catalogue covers galvanised, carbon-steel and stainless ductwork, spiral sections, common-plate and angle-steel flanges, air outlets, valves, fans and customised environmental equipment. Design, manufacture and construction/installation are presented together; the quotation still needs to identify which activities belong to the supplier’s contracted scope.

There is a significant identity distinction. The actual business-licence image in the official honour gallery names 绵阳市涪城区精鑫风管加工厂, a sole proprietorship, and prints an establishment date of 19 August 2013. The current profile uses the limited-company name and a 2013 history statement; the product description also ends with the processing-factory name. This image does not authenticate the current limited company’s incorporation or establish the legal relationship between the two entities. Ask for the current contracting licence and invoice/bank details before ordering.

Current site name
四川精鑫通风设备有限公司Official profile/contact identity; current registry status not independently authenticated. Source
Displayed licence holder
绵阳市涪城区精鑫风管加工厂 · sole proprietorshipActual image inspected; establishment 2013-08-19 belongs to this named entity. Source
Official contact location
Zaojiaopu building-materials market · Xinzao · Fucheng · MianyangA market/workshop address, not a verified site-area measurement. Source
Production statements
6,000+ m² · 30+ employees · over 1,000 m² dailySupplier profile figures; no audited capacity, shift or order-mix basis provided. Source
02 / EQUIPMENT

Published equipment and selection evidence

Custom spiral and rolled duct catalogue
series REFERENCE

Custom spiral and rolled duct catalogue

Catalogue reference: Custom spiral duct catalogue

Open the equipment selection brief
Parameters and source limits · Custom spiral duct catalogue

Swipe the table, or focus it and use arrow keys, to read conditions and sources.

Manufacturer-published information · Custom spiral duct catalogue
ParameterPublished valueConditions and evidence
Reviewed item绵阳螺旋风管 · spiral circular duct familyNo fixed model designation or stock-size schedule provided. Source
Material descriptionsGalvanised for ordinary ventilation; stainless for corrosive/damp settingsGrade, coating and exposure limits are not published; actual material must be selected. Source
Cold-air descriptionInsulation required; internal lining is mentioned as an optionNo insulation thickness, fire class, conductivity or vapour-barrier specification provided. Source
Numerical order dataDiameter, gauge, section length, joint and pressure/leakage criteria to confirmNo ratings inferred from photos or general feature claims. Source
03 / PROJECT REVIEW

Assess Jingxin through the actual duct package

Choose the fabrication route by geometry and connection

The profile lists several duct production lines, including “fifth-line” and “sixth-line” wording, and dozens of dedicated machines. Those statements do not establish the diameter/gauge envelope of a spiral machine or the capability of every listed material. Treat the spiral, common-plate flange and angle-steel flange families as separate fabrication packages.

Provide a coordinated duct drawing and numbered schedule for straights, elbows, reducers, branches and transitions. Identify whether dimensions refer to clear internal air space or external fabricated dimensions, particularly where insulation is included. Ask who develops shop drawings and resolves clashes with structure, cable trays or other services before fabrication begins.

Spiral circular sections

Confirm diameter, sheet gauge, seam, end treatment and matching fittings; the reviewed spiral item has no numerical range.

Common-plate flange duct

Approve formed flange dimensions, corners, fastening/sealing and reinforcement for the actual section sizes.

Angle-steel flange duct

Specify flange section, hole pattern, welding/finish and gasket rather than assume interchangeability with formed flanges.

Specify material instead of buying by appearance

The spiral description proposes galvanised duct for ordinary ventilation and stainless for corrosive or particularly damp locations. It provides no steel grade, zinc-coating specification, stainless grade or chemical exposure limits. The appearance of a bright metallic tube cannot settle those requirements. Ask for the sheet specification and traceable material documents tied to the delivered batch.

Choose material against the actual air stream, humidity, contaminants and cleaning method with the responsible designer. For a cold-air system, decide insulation thickness, conductivity, vapour barrier and support details separately. A supplier’s ability to fabricate stainless duct is not proof that an unspecified stainless grade is suitable for every corrosive process.

Keep smoke and kitchen applications separate from general ventilation

The site has a separate smoke-exhaust category and the spiral text also mentions kitchen fume exhaust. Neither establishes a certified fire-resistance period, smoke temperature/time rating or grease-duct approval for the reviewed spiral assembly. General ventilation benefits such as “good sealing” and “low noise” have no measured leakage class or acoustic data on that page.

For smoke, fire or grease service, have the responsible designer specify the complete approved construction and installation requirements. Obtain evidence covering the actual material, seams, joints, supports, insulation and service conditions. Do not infer a compliant system from a category title or apply a general supplier article as universal code advice.

Read capacity and case evidence with their limits

The daily output statement uses square metres without defining whether it is developed sheet area, finished duct area, shifts, gauge or fitting mix. A project with many transitions and branches cannot be scheduled from that headline alone. Ask for a production plan based on the approved schedule, material procurement, bottleneck operations and installation sequence.

The official gallery lists Mianyang Central Hospital, the public-security bureau, Red Star Macalline and a partly masked school name with testimonial-style text. These are supplier-hosted references. The reviewed pages do not supply client-issued acceptance documents, bill-of-quantities or exact delivered duties, so they are not represented here as independently verified endorsements.

Use the licence image as identity evidence, not product approval

The displayed licence can support the named processing factory’s historical identity and business scope. It cannot certify pressure strength, leakage, fire resistance or stainless material quality. No current limited-company registration, accredited duct test or model certificate was authenticated in this review. The distinction remains explicit instead of being filled with a generic certification badge.

Require the document relevant to the intended transaction: current company licence for contracting, batch material evidence for sheet selection, and the agreed inspection/test record for the assembly. Verify any certificate’s holder, product scope, report number and validity against the actual order.

Actual licence image

Names the sole proprietorship and its 2013 establishment; does not prove a later company relationship.

Read the source

Official spiral product page

Application and construction descriptions without a rated diameter/gauge/pressure or leakage table.

Read the source

Supplier case gallery

Named references and supplier-hosted testimonials; no client acceptance authenticated.

Read the source

Hand over a duct system that can be installed and checked

The official contact email remains in the private CRM field. No email has been sent. The reviewed source establishes no universal price, MOQ, warranty or delivery commitment; define these for the approved package.

  1. Approve the order

    Confirm the contracting entity, drawings, material/gauge, connections, reinforcement and installation boundary.

  2. Inspect the fabrication

    Check labelled dimensions, seams/flanges, fitting fit-up, finish and material traceability; agree pressure/leakage checks with acceptance criteria.

  3. Release by installation zone

    Pack and label by drawing/zone, protect edges and openings, verify transport/lifting access and record site joints, supports and final inspection.

07 / TRANSPARENCY

Sources and review scope

Compiled by HVACDeck Editorial. Page review: 2026-10-11. Publications are attributed below; their statements are not independent measurements by this platform.

  1. Official current company profileChecked 2026-10-11 · Actual profile read; 2013, plant/staff/production figures remain supplier statements.
  2. Official honour gallery and actual licence imageChecked 2026-10-11 · Embedded image inspected at enlarged size after direct CDN URL returned403; holder is a sole proprietorship, not the current company name.
  3. Official contact detailsChecked 2026-10-11 · Actual current name/address read; official email retained privately.
  4. Official spiral duct itemChecked 2026-10-11 · Actual application text and embedded product image read; no numerical selection table.
  5. Official plant/case galleryChecked 2026-10-11 · Actual gallery/case captions and testimonial text read; not a site audit or independent client acceptance.