01 / COMPANY

What this manufacturer offers

Zhejiang Sino King Refrigeration publishes a broad HVAC and refrigeration portfolio from its Dongyang company website. Its stated activities include equipment design, research, production, sales and service, with customized and differentiated products central to its declared strategy. This profile focuses on the evidence useful when buying its water-cooled screw low-temperature refrigeration family.

The company describes two branches and more than a thousand staff, but those are company-wide statements without a current headcount or order-specific production allocation in the reviewed material. They do not establish the capacity available for the requested delivery date.

The external records reviewed here support a named company and a separate SKZK evaporatively cooled product listing. Neither is a factory audit or a performance approval for the low-temperature screw unit. The first procurement task is to identify the contracting entity, manufacturing site and precise cooling duty in the same offer.

Published Chinese company name
浙江思科制冷股份有限公司Official company identity; also named in the 2021 Zhejiang securities-regulator notice. Source
Published contact address
1233 Guangfu East Street, Liushi Subdistrict, Dongyang, ZhejiangOfficial footer address. Confirm the actual production and dispatch location for the selected order. Source
Corporate scale statement
Two branches; more than 1,000 staffManufacturer-wide self-report, not independently audited current capacity or personnel assigned to this product. Source
02 / EQUIPMENT

Published equipment and selection evidence

Water-cooled screw low-temperature refrigeration family
series REFERENCE

Water-cooled screw low-temperature refrigeration family

Catalogue reference: Low-temperature screw family

Open the equipment selection brief
Parameters and source limits · Low-temperature screw family

Swipe the table, or focus it and use arrow keys, to read conditions and sources.

Manufacturer-published information · Low-temperature screw family
ParameterPublished valueConditions and evidence
Published equipment familyWater-cooled screw low-temperature refrigerationFamily reference; no exact orderable model schedule established. Source
Published secondary-fluid alternativesEthylene-glycol solution or calcium-chloride solutionAlternatives stated by the manufacturer. Concentration, compatibility and allowable temperatures remain selection questions. Source
Heat-rejection requirementCooling tower or another cooling-water sourceRequired external water-side arrangement in the product text; flow, temperatures, quality and pressure drop are not published. Source
03 / PROJECT REVIEW

Review the supplier behind a low-temperature process-cooling offer

Three dates describe different kinds of history

The company overview separates a brand-origin date from formation and renaming. The detailed timeline is more specific about the businesses named at each stage. Preserve those distinctions when checking an old drawing, certificate or quotation.

1966: brand origin claim

The overview labels 1966 as brand creation. It does not say that the present Chinese legal entity was registered in 1966.

Read the source

2005 and 2010: predecessor businesses

The timeline says Zhejiang Huilong Air Conditioning Equipment was established in 2005 and Zhejiang Sike Guoxiang Refrigeration Equipment in 2010. No registry documents establishing each transfer or legal succession were reviewed.

Read the source

2017: present name in the timeline

The company records a change to 浙江思科制冷股份有限公司 on 6 February 2017. For an order, match the current entity on the contract, invoice and applicable certificates.

Read the source

Keep process refrigeration separate from comfort cooling

The reviewed low-temperature publication describes a screw unit supplying a medium- or low-temperature secondary coolant, with a cooling tower or another cooling-water source required. It names ethylene-glycol and calcium-chloride solutions as alternatives. This is a different selection task from an ordinary comfort-cooling water schedule.

The broader catalogue also groups water-cooled equipment/heat pumps, air-cooled equipment/heat pumps, terminal products, commercial units, refrigeration and integrated systems. These divisions show the published offer; they are not proof that a given selection is suitable for every pharmaceutical, agricultural or industrial process.

Ask which team will select the low-temperature unit and who is responsible for the secondary-fluid circuit and heat-rejection equipment. The separate product review below sets out the missing duty and integration data. No outlet-temperature range, refrigerant, cooling capacity or food/pharmaceutical compliance has been inferred.

Water-cooled low-temperature screw family

Review against coolant chemistry, temperature and process duty. The public family text has no exact model-by-model rating table.

Read the source

SKZK evaporatively cooled equipment

A separate external listing names this different family. Its standard and published service terms cannot be transferred to the low-temperature screw unit.

Read the source

Factory expansion and laboratory claims need an order-specific check

The company history records initial production stages in 2011–2012, five laboratories in 2019, a third-phase plant construction start in 2025 and a CNAS laboratory-recognition claim in 2026. These are statements on the company’s timeline. No accreditation number, scope schedule, expiry record or low-temperature test capability was established from the readable history.

The factory-gallery page publishes facility photographs without usable captions identifying each line, date, throughput or inspection activity. A photograph and an expansion announcement do not establish the current status of a particular line.

Request the manufacturing address, proposed assembly/test location, applicable laboratory scope and the selected unit’s inspection plan. If the offer relies on an accredited test, match the actual test method, range, laboratory and report to that claim. No current annual output or factory-completion date has been added.

External records: useful identity evidence with limited scope

The Zhejiang securities regulator published a notice naming this company on 2 September 2021 under IPO counselling filings. This confirms the named historical filing; it does not establish a present stock-market listing, an approved offering or equipment certification.

The Zhejiang Made platform separately lists SKZK evaporatively cooled screw equipment at Guangfu East Street 1233 and cites T/ZZB 0406—2018. Its company biography repeats supplier statements. The listing is not evidence that every Sino King family has the same certification or verified performance.

Use these records to cross-check the entity and distinguish product families. Request current, identifiable certificates and their exact scope for the ordered equipment rather than relying on corporate awards or a generic three-systems-certification statement.

Write service responsibilities around the actual process

The official company overview describes nationwide sales offices and internet-assisted service, without publishing a destination-specific service agreement for the low-temperature family. A network description does not establish who will attend an overseas site or how quickly the required part will arrive.

Agree selection responsibility, supply boundaries, commissioning, operator training, spare parts and local support before placing the order. The following outline is an editorial purchasing workflow, not a service commitment made by the manufacturer.

  1. Name the supplying and attending parties

    Match the contract entity and factory, and identify the organisation responsible for startup and fault attendance at the project location.

  2. Separate equipment from system work

    List the chiller, secondary-fluid circuit, cooling-water/tower system, controls, wiring, installation and commissioning responsibilities. Mark exclusions explicitly.

  3. Agree a handover package

    Obtain the selected model/duty sheet, manuals, drawings, alarm/protection documentation, acceptance records and written warranty/support terms for this specific family.

07 / TRANSPARENCY

Sources and review scope

Compiled by HVACDeck Editorial. Page review: 2026-10-11. Publications are attributed below; their statements are not independent measurements by this platform.

  1. Sino King company overviewChecked 2026-10-11 · Full company description and separate brand/formation/renaming labels read.
  2. Official development historyChecked 2026-10-11 · Named predecessors and expansion/laboratory claims read; not independently verified current production or accreditation.
  3. Water-cooled screw low-temperature refrigeration publicationChecked 2026-10-11 · Secondary-coolant, cooling-water, oil-management and protection descriptions read; no exact numerical rating table.
  4. Zhejiang Made SKZK product listingChecked 2026-10-11 · External platform record for a different evaporatively cooled family; its standard and service scope not generalized.
  5. Zhejiang securities-regulator historical noticeChecked 2026-10-11 · 2 September 2021 counselling-filing notice; not proof of present listing or product approval.
  6. Official factory galleryChecked 2026-10-11 · Facility-image publication without identified line capacity or usable inspection captions.

How we review sources · Represent this factory or request a correction

Continue your equipment research

Prepare your equipment brief