MANUFACTURER / SOURCE REVIEW

Sunfly · Zhejiang Xinfan HVAC Intelligent Control

Zhejiang Sunfly HVAC Intelligent Control Co., Ltd.

Yuhuan hydronic components and system-solutions business: separate the brass manifold order from the wider heating and control package.

台州市, 浙江省, China

Prepare a technical enquiry
1 published equipment referenceLatest source review 2026-10-11
01 / COMPANY

What this manufacturer offers

Sunfly’s Chinese company overview traces a workshop beginning in 1998 and creation of the Xinfan brand in 2001. It describes development from copper fittings and angle valves into brass distribution manifolds, thermostatic and radiator valves, mixing systems and complete heating solutions. These history statements distinguish the origin of the business and brand; they do not establish the incorporation date of today’s joint-stock entity.

The official contact page names 浙江鑫帆暖通智控股份有限公司 and publishes an address in the Qinggang industrial cluster, Yuhuan, Zhejiang. Its English navigation links the hosted catalogue where the identified XF20160H manifold has a readable specification. The manifold is a useful concrete reference for supplier qualification, but its component data cannot describe the whole company’s system offerings.

An original national-standard record also names this company as a drafting organisation for the current cold/hot-water manifold standard. Keep that contribution separate from a model-specific conformity report, a factory audit or a commitment to install and support a complete project.

Exact company name
浙江鑫帆暖通智控股份有限公司Official contact page and national-standard drafting record use the same entity. Source
Published contact location
Qinggang industrial cluster, Yuhuan, ZhejiangCompany address in the contact text; not an independent survey of the order’s production site. Source
Business and brand timeline
Workshop origin 1998; Xinfan brand 2001Official narrative. Neither date is treated as the current entity’s verified incorporation date. Source
Named standards contribution
GB/T 29730-2025 drafting organisationOfficial issuer’s current record. Drafting participation is not XF20160H certification. Source
02 / EQUIPMENT

Published equipment and selection evidence

Parameters and source limits · XF20160H

Swipe the table, or focus it and use arrow keys, to read conditions and sources.

Manufacturer-published information · XF20160H
ParameterPublished valueConditions and evidence
ModelXF20160HExact identifier on the English catalogue page. Confirm current revision and ordered configuration. Source
Declared body materialCW603N brassThe page describes Italian-imported brass; origin, batch composition and application suitability not independently verified. Source
Published nominal pressure≤10 barListing limit; no pressure-temperature derating or test method supplied. Source
Published working temperature≤100°CListing limit; simultaneous operation at 10 bar/100°C not established. Source
Outlet count and spacing2–12 ways; 50 mm branch spacingOrder the required number of circuits; obtain the matching dimensional drawing. Source
Header size options1 inch / 1¼ inchPublished size string interpreted as alternatives; thread gender and port assignment require a drawing. Source
Branch connections3/4 inch × 16; 3/4 inch × 20Catalogue notation. Confirm adapter, pipe material/wall size and supplied connection parts. Source
Actuator interfaceM30 × 1.5Mechanical thread only; voltage, stroke, force and control compatibility not specified. Source
Connection thread referenceISO 228Manufacturer statement; exact thread designation, seal and mating connection must be specified. Source
03 / PROJECT REVIEW

Review the component configuration and system responsibility separately

A manifold, a mixing package and a complete system are different orders

The company’s catalogue separates manifolds, mixing systems, thermostatic valves, radiator valves and temperature-control panels/electric actuators. That range offers several potential purchasing scopes. Determine whether the contract concerns an identified component, a coordinated assembly or design/installation of a complete heating system.

Component supply

For XF20160H, specify ways, header and branch interfaces, material, pressure-temperature conditions, included parts and documentation. Its detail page provides a model identifier and connection figures.

Read the source

Mixing and control package

Obtain an itemised pump/valve/control arrangement with its own selection data and interface drawing. These items are not established as included by the manifold page.

Complete heating solution

Agree heat-source and circuit design, site interfaces, installation/commissioning scope and responsible service parties. The overview’s solutions statement does not by itself define a project contract.

Read the source

The overview identifies a process approach, not a current factory audit

Sunfly describes professional CAD design, precision machine tools and a complete product-management and inspection approach. It also gives patent and broad ISO/CE/“ROSH” certification statements. The readable overview does not identify a current certificate number, covered site/model schedule or a batch inspection record for XF20160H. The spelling on the source is not used here as proof of a particular chemical-compliance test.

Qualify the actual order with a current site/process description, approved drawings, material traceability and configuration-specific inspection plan. Ask how valves, seals, threaded connections and supplied adapters are identified and checked, and how design changes are controlled. Patent totals and engineering software names do not establish a supplied unit’s leakage performance or material conformity.

What the standard issuer confirms

The national standards platform lists 浙江鑫帆暖通智控股份有限公司 among the drafting organisations for GB/T 29730-2025, Distribution manifold of cold/hot water. It marks the standard current, published 1 August 2025 and implemented 1 February 2026, replacing GB/T 29730-2013.

This is original issuer evidence of participation and the applicable standard’s edition/status. It does not declare every Sunfly product compliant or supply a test report for a named order. If the buyer specifies that standard, require the supplier to identify the exact edition and provide the relevant model/configuration evidence. No complete technical-clause audit or independent factory test was performed by this platform.

Use XF20160H to test how clearly the supplier defines its offer

The English detail gives CW603N brass, nominal pressure up to 10 bar, working temperature up to 100°C, 2–12 ways and 50 mm spacing. It identifies an M30 × 1.5 actuator connection and branch options written as 3/4 inch × 16 or × 20. The detail does not provide hydraulic curves, an actuator electrical specification or a complete bill of materials.

A clear quotation should resolve these gaps rather than repeat the catalogue. The main photograph illustrates a five-way pair with white caps; it does not establish powered actuators or flowmeters included. Ask for the matching drawing, interface schedule, parts and versioned instructions. This concrete review helps distinguish a documented assembly from a generic brand-level capability claim.

  1. Submit the circuit and connection schedule

    Give the number of circuits, pipe sizes/materials, design flows and intended controls. State which accessories are to be included.

  2. Review the identified assembly

    Match header size, branch adapters, actuator compatibility, dimensions, limits and hydraulic evidence to the project.

  3. Agree quality and handover

    Confirm inspection/traceability requirements, current instructions, spare-part identifiers, warranty and service at the actual destination.

Resolve entity, document and service scope before a deposit

The official contact page’s direct text gives the Yuhuan address and names the joint-stock company. Its embedded third-party map search can display a different location result, which is not adopted as the factory address here. Reconcile the legal entity, actual production/delivery location and bank/contract documents through the supplier’s current approved information.

The source links an English catalogue on a web-hosting subdomain. That link establishes the catalogue’s connection to the Chinese site, but not a separate overseas legal entity or regional service organisation. Obtain current English drawings and instructions, the responsible commercial/technical contact, support arrangements and replacement terms for the ordered product. No destination-specific attendance promise or warranty duration was established in the reviewed sources.

07 / TRANSPARENCY

Sources and review scope

Compiled by HVACDeck Editorial. Page review: 2026-10-11. Publications are attributed below; their statements are not independent measurements by this platform.

  1. Sunfly official Chinese company overviewChecked 2026-10-11 · Full origin/brand narrative, component and system scope, machining/inspection and certification claims read; certificate scope not established.
  2. Official Chinese contact publicationChecked 2026-10-11 · Direct text gives Yuhuan address and company name; map-search results not treated as factory identity. English hosted catalogue link verified. Email retained privately.
  3. Official-linked English XF20160H detailChecked 2026-10-11 · Full specification and main image individually reviewed; component limits do not specify a complete heating system.
  4. National-standard issuer: cold/hot-water manifold recordChecked 2026-10-11 · Current GB/T 29730-2025 and company drafting role read; no model certification inferred.

How we review sources · Represent this factory or request a correction

Continue your equipment research

Prepare your equipment brief