1 published equipment referenceLatest source review 2026-10-11
01 / COMPANY
What this manufacturer offers
Huzhou Yaoniu HVAC Equipment Co., Ltd. names its Zhejiang headquarters in Tanglou Village, Yangxi, Zhili Town, Wuxing District, Huzhou. The site title also uses Zhejiang Yaoniu, while its introduction and footer identify 湖州耀牛暖通设备有限公司. This profile follows the named Huzhou entity rather than treating the provincial branding as a separate registered company.
The company describes air-conditioning ventilation design, installation and commissioning, metal components, spiral ducts and fittings. Its catalogue distinguishes galvanized rectangular and spiral ducts, integral and angle-steel flanges, insulated ducts, welded ducts, stainless-steel ducts, dampers, silencers and plenums. The scope is a fabrication and installation discussion, not proof that every listed accessory is manufactured at one site.
The reviewed pages contain specific equipment names and also conflicting production statements. They support questions about forming, joining and drawing-based delivery, but do not establish a verified daily capacity or an independently accepted project history.
Named company
湖州耀牛暖通设备有限公司 / Huzhou Yaoniu HVAC Equipment Co., Ltd.Official introduction and footer; Zhejiang wording is used in the website title. Source
Headquarters location
Tanglou Village, Yangxi, Zhili Town, Wuxing District, Huzhou, ZhejiangCompany-published address; the detailed location states west of Santang Road. No independent site audit. Source
Published fabrication formats
Rectangular, spiral, integral-flange and angle-steel-flange ductworkNamed catalogue categories, not a single standardized construction or pressure class. Source
Parameters and source limits · Galvanised sheet-metal ducts
Swipe the table, or focus it and use arrow keys, to read conditions and sources.
Manufacturer-published information · Galvanised sheet-metal ducts
Parameter
Published value
Conditions and evidence
Material family
Galvanized sheet steel
Manufacturer description; grade, coating designation/mass and ordered thickness must be specified. Source
Published shapes and construction routes
Rectangular and spiral-round descriptions; integral and angle-steel flange catalogue divisions
Separate routes within the catalogue, not one shared tested configuration. Source
Manufacturing-envelope claim
Homepage states 0.4–2 mm sheet processing and spiral diameter up to 2.4 m
General supplier claim, not an allowable gauge/diameter combination or pressure class for every product/material. Source
03 / PROJECT REVIEW
Define the fabrication package before relying on the headline capacity
Separate the legal supplier, fabrication site and installation team
The footer publishes addresses in Zhejiang, Nanjing, Anhui and Henan. The introduction does not establish their separate legal identities or which workshop will manufacture an order. Request the contracting entity, the actual fabrication address and the installation or subcontracting scope in the offer. Company branding alone does not settle those responsibilities. (Sources 1 and 2.)
The introduction describes design, installation and commissioning as services. This does not establish a commissioning result for the buyer's project or a universal destination-market approval. Ask who is responsible for drawings, material approval, site measurement, installation inspection and final acceptance.
Use the machinery descriptions to ask focused production questions
The company names SPIRO-related spiral-duct and fitting equipment, including JPX forming, R1530 plasma cutting and CU-30 seam joining, plus locking, punching, folding, shearing and flange-forming equipment. It also lists automated rectangular lines, laser equipment and angle-flange welding. These are company-published equipment statements without an independent asset audit, current machine-condition report or tolerance schedule. (Source 2.)
Rectangular duct and flange work
Ask which drawing-controlled seam, flange, corner and reinforcement details will be used. A forming-line count alone does not determine the ordered duct's leakage or pressure performance.
Identify diameter, sheet material, seam and fitting construction. The homepage's general diameter and sheet-processing envelopes are not limits proven for every material and order.
The daily-output and cost-saving claims need a basis
The homepage states 3,000 square metres per day for rectangular ducts and 300–1,000 metres per day for round ducts. The introduction separately says daily output of ten thousand square metres. Neither reviewed page defines whether the figures concern one line, one site, all sites, one shift, a particular material or the same product mix. They cannot be combined into a verified plant capacity. (Sources 1 and 2.)
Ask for the order-specific production slot, drawing quantity, material availability, inspection scope and delivery schedule. The homepage's 30% cost-saving wording also lacks a comparable baseline and project conditions, so it is not used as a promised saving or quote discount.
Historical quality-system wording is not current certification
The introduction says its quality system was established according to ISO9002. It gives no certificate number, issuer, holder, edition or current status. ISO's own record marks ISO 9002:1994 as withdrawn. The company statement therefore cannot be presented as current certification or as product conformity. (Sources 2 and 5.)
An exact Chinese-name search restricted to government domains returned no matching public result during this review. That search gap is not proof that the company lacks registration or approval. Obtain current legal and quality documents, identify their scope, and verify them with the issuing body where relevant.
The site names projects such as metro, commercial and pharmaceutical buildings, but the reviewed homepage does not establish contract scope, completion, client acceptance or current reference permission. These remain supplier-published project names, not independently validated deliveries.
Build an order around the drawing and inspection revision
A useful enquiry for this supplier identifies the required fabricated assemblies, rather than asking only for galvanized ductwork. The steps below are editorial procurement guidance, not a description of an already completed Yaoniu order.
Freeze the construction schedule
Provide geometry, sheet grade and coating, sheet thickness by section, seam, flange, reinforcement, accessories and drawing revisions. Separate insulated, welded and spiral work where their construction differs.
Agree the inspection basis
Specify dimensions and tolerances, material records, joint/seal requirements, pressure and leakage acceptance, and the evidence required for any special fire or clean-room duty.
Confirm production and site responsibility
Name the actual fabrication site, agreed production slot, shipment identification, installation scope and handover records. Resolve the conflicting output statements before relying on a schedule.
07 / TRANSPARENCY
Sources and review scope
Compiled by HVACDeck Editorial. Page review: 2026-10-11. Publications are attributed below; their statements are not independent measurements by this platform.
Huzhou Yaoniu company introductionChecked 2026-10-11 · Named entity, equipment descriptions, ISO9002 wording and different daily-output claim read; no asset or certificate audit.
Galvanized ductwork catalogueChecked 2026-10-11 · Catalogue divisions and headquarters/branch address wording read; categories do not establish one construction.
Galvanized sheet-metal duct publicationChecked 2026-10-11 · Full article read. Rectangular, spiral and connection wording mix; universal leakage claims not treated as measured results.