Rectangular ducts
Give width and height, sheet schedule, seam, reinforcement and flange. Put irregular fittings and transitions in the approved drawing set.
Read the sourceGalvanized rectangular and spiral ducts fabricated to drawing, with the section, seam and flange chosen together for each order.
From Huzhou Yaoniu HVAC Equipment Co., Ltd.
Product guide · HVACDeck Editorial · Sources checked 2026-10-11
Yaoniu fabricates galvanized sheet-metal ductwork in several constructions. Its catalogue lists insulated ducts, rectangular ducts, integral-flange ducts, angle-steel-flange ducts, spiral ducts and ducts for purification systems. Each is a separate way of building a duct run, so an order needs a drawing that fixes the shape, the sheet, the joining system and the duty.
Yaoniu's product article covers mechanical forming and seam work on rectangular and irregular sections, then spiral round ducts and their uses. The homepage gives a working range of 0.4–2 mm sheet and spiral diameters up to 2.4 m. The article describes spiral construction as leak-free without a test pressure or leakage class behind it. To get a comparable price, send drawings with your pressure and leakage requirement and ask Yaoniu to quote the matching assembly.
This is an equipment family; ask the manufacturer to select the model that matches your duty.
Swipe the table, or focus it and use arrow keys, to read the conditions and sources.
| Parameter | Published value | Conditions and sources |
|---|---|---|
| Material | Galvanized sheet steel | State the steel grade, coating designation or mass and the thickness you need. Source |
| Shapes and construction routes | Rectangular and spiral round ducts; integral-flange and angle-steel-flange catalogue divisions | Each route has its own drawing and joint; pick one per duct run. Source |
| Stated production range | 0.4–2 mm sheet processing; spiral diameter up to 2.4 m | Homepage figures for the plant. Ask which gauge and diameter combinations Yaoniu builds for your pressure duty. Source |
The article describes seams, forming and a spring-clip flange arrangement. The catalogue lists integral and angle-steel flanges in separate columns. Ask for the drawing of the joint Yaoniu proposes, including gasket and reinforcement, so you know exactly what the price covers.
Round and rectangular ducts need different drawings and fittings. Pressure and acoustic behaviour also differ, so judge each route on its own data.
Give width and height, sheet schedule, seam, reinforcement and flange. Put irregular fittings and transitions in the approved drawing set.
Read the sourceGive diameter, sheet and seam, fitting system and end connections. The 2.4 m maximum is a plant limit; your diameter still needs a structural and pressure selection.
Read the sourceSpecify insulation, vapour barrier, inner surface finish and project acceptance as separate line items. Ask for the cleanliness or thermal data that goes with the assembly you order.
Read the sourceYaoniu's article calls its spiral construction leak-free but gives no test pressure, test method, sample or allowable leakage figure. Write the leakage class and test you need into the enquiry instead.
Ask Yaoniu to quote the run against your positive and negative pressure and the leakage acceptance. Seams, flanges, gaskets, sealant, reinforcement and supports all belong in that scope. Request a pressure and leakage test on a sample section as part of the order; the factory acceptance and pressure test guide sets out how to word it.
The article names supply air, cooled air, kitchen exhaust, dust collection and conveying of bulk material as uses. It also separates humid or corrosive conditions from normal galvanized service.
For grease, condensate, dust, abrasive material or corrosive air, describe the medium, temperature and cleaning access. Then agree a matched construction and acceptance test with the designer and Yaoniu. Fire rating, corrosion allowance, abrasion life and cleaning method all need stating per order. If the run is insulated, ask for thickness, conductivity and vapour-barrier details of the delivered insulation; the insulation itself can be compared with products such as Heqiang PEF insulation.
One drawing-based requirement sent to all bidders keeps quotations comparable. Other fabricators listed here, such as Luhai spiral ducts, quote from the same kind of brief.
Drawing revision, quantities, shape and sizes, sheet grade and coating, thickness schedule, fittings, flange or seam system, insulation and access doors.
Air or medium, flow, temperature, positive and negative pressure and the leakage and material acceptance. Ask the bidder to flag any duty outside its normal range before pricing.
Separate fabricated duct, flanges, seals, supports, packing, delivery and site installation. Ask for material and inspection records and the pressure and leakage results for the selected assembly.
Before ordering, ask Yaoniu to confirm in writing: the gauge schedule for each size; the flange or seam system and gasket; the pressure class and leakage class the run will meet, with the test used; any fire, corrosion or noise rating you require; the insulation specification; the valid quality certificate; and price and shipment slot. The company itself, its sites and its differing output figures are covered on the Huzhou Yaoniu company page. Fix those items in the contract together with the approved drawings.
Compiled by HVACDeck Editorial. Figures are as published by the manufacturer; ask for test records for the unit you select.
Editorial method and corrections · Report a detail with this page URL
Send the manufacturer your required duty, installation conditions and the points listed above to confirm.