MANUFACTURER / SOURCE REVIEW

Annaite · building ventilation fans, cabinets and fire-system variants

Zhejiang Annaite Ventilator Manufacture Co., Ltd.

A Shangyu fan manufacturer whose catalogue separates building, industrial and smoke duties; compare exact configurations and evidence, not catalogue badges.

绍兴市, 浙江省, China

Prepare a technical enquiry
1 published equipment referenceLatest source review 2026-10-11
01 / COMPANY

What this manufacturer offers

浙江安耐特风机制造有限公司 identifies its location in Tangpu, Shangyu, Shaoxing. Its official catalogue groups fans by civil/commercial buildings, warehouses, underground spaces, industrial ventilation and fire/duct components. The reviewed DBF entry is unusually useful because its original images contain model coding, twelve air-port arrangements and separate A/E performance tables.

DBF ordinary ventilation and the modified DSF smoke-extraction version are different purchasing decisions. The source’s high-temperature statement belongs to DSF; it cannot be applied to a normal DBF quotation. The displayed certificates and test report also name different subjects, so each must be matched to the proposed fan rather than treated as company-wide approval.

The official service commitment states defined time periods and exclusions. Those are supplier promises, not measured response history or an overseas service contract. The review below connects the available construction and selection evidence to the documents a buyer still needs.

Official entity
浙江安耐特风机制造有限公司Official introduction/contact and original patent publication identify this entity. Source
Published location
East of the petrol station, Tangpu Town, Shangyu District, ShaoxingOfficial contact/location wording; not a current factory inspection. Source
Reviewed cabinet family
DBF ventilation / modified DSF smoke extractionDifferent duties in one catalogue detail; ordinary DBF does not inherit DSF high-temperature claims. Source
Published warranty starting point
12 months from dispatch from the factoryManufacturing-quality faults covered under supplier wording; destination and written order terms require agreement. Source
Original technical publication
CN211550023U — diagonal-flow fan2020 utility-model publication, a different subject from DBF cabinet selection; no current rights determination. Source
02 / EQUIPMENT

Published equipment and selection evidence

Parameters and source limits · DBF

Swipe the table, or focus it and use arrow keys, to read conditions and sources.

Manufacturer-published information · DBF
ParameterPublished valueConditions and evidence
A-type DBF40 table example4,000 m³/h · 373 Pa · 0.8 kW × 1A-fan table; 930 rpm, listed noise 60 dB(A), reference weight 180 kg. Not a complete fan curve or installed acoustic guarantee. Source
E-type DBF40 row a example4,000 m³/h · 330 Pa · 0.75 kWE-fan table row a; listed cabinet noise 66 dB(A), reference weight 280 kg. Pressure terminology needs confirmation. Source
E-type DBF40 row b example4,000 m³/h · 495 Pa · 1.1 kWE-fan table row b; listed noise 68 dB(A), reference weight 290 kg. Different selection from row a. Source
Published port arrangements12 numbered inlet/outlet arrangementsOriginal diagram; actual order still requires a signed orientation/access drawing. Source
03 / PROJECT REVIEW

Assess Annaite around the fan configuration and installed duty

Use the catalogue groups to identify a duty, then choose a specific fan

The navigation separates cabinet centrifugal fans, axial/mixed-flow/diagonal-flow fans, roof and wall units, tunnel fans, high-pressure centrifugal equipment and fire/duct accessories. A building-ventilation brief is therefore not a general request for any product under the same logo.

Provide airflow, pressure definition, air condition, installation layout, electrical supply and acoustic requirements. State whether the system is ordinary ventilation, a process application or smoke extraction. Ask the supplier to identify the exact family/configuration and the evidence needed for that system, including any duty outside the ordinary ventilation table.

Ordinary building ventilation

The reviewed DBF cabinet offers detachable construction and alternative port layouts, with A/E table entries to examine.

Read the source

Smoke-extraction duty

Require a specifically selected smoke configuration and its applicable test/certification evidence; do not assign DSF wording to DBF.

Read the source

Industrial or specialist duty

Select the applicable fan family and materials/protection requirements separately; a general catalogue listing supplies no universal hazardous-area approval.

The DBF construction helps plan access and acoustic requirements

The source describes a detachable metal frame and panel construction, galvanised sheet for impeller/casing, coloured outer panels, an inner microperforated galvanised acoustic sheet and fine glass-wool infill. Aluminium-alloy frame profiles are described as an option. Suspended and floor installation are discussed.

These construction details help a buyer specify maintenance openings, cabinet dismantling and access to the selected motor/drive arrangement. They do not establish a guaranteed room sound level or a fixed corrosion class. Ask for the actual panel/material specification, selected orientation, lifting/support details and access envelope on the approved drawing.

Match certificate images to their named products and dates

The inspected ARES ISO9001:2015 image states validity to 5 April 2025; the inspected Certification Europe quality, environment and occupational-health/safety images state 7 March 2025. These displayed periods are past at the review date. Current renewed status was not authenticated. Management certification is also separate from a fan’s performance or fire duty.

The energy-efficiency report cover dated 21 July 2022 identifies SWF-13, not DBF, and supplies no reviewed result pages. The inspected BDWEX-900 explosion-protection image identifies a wall axial fan and states validity to 6 July 2025. Samples inspected in the fire-certificate gallery are attachments for fire dampers under certificate Z2019081814010780; an attachment says it must be used with its certificate. None is adopted as proof of DBF or DSF approval.

Management-system images

Historical displayed validity periods have elapsed; obtain readable current documents and issuer/scope verification.

Read the source

SWF-13 report cover and BDWEX certificate

Different products from DBF; a cover alone does not establish an efficiency result, and the inspected explosion certificate has a past stated expiry.

Read the source

Fire-damper attachments

Inspected samples concern FHF damper configurations and require the parent certificate; they are not cabinet-fan test evidence.

Read the source

An original patent publication is a defined technical record

The original CN211550023U utility-model publication names 浙江安耐特风机制造有限公司, gives a 13 January 2020 filing date and a 22 September 2020 publication date, and describes a diagonal-flow fan with motor support, guide vanes and associated features.

That publication documents a technical subject and named holder at publication. It is not a DBF cabinet specification, an authenticated current-rights report, a high-temperature test or proof of all patent counts advertised by the supplier. No patent-wide performance claim is transferred into the selected cabinet offer.

Read the after-sales promise by starting point, fault cause and geography

The supplier states a twelve-month guarantee from factory dispatch, with free repair for manufacturing-quality faults in that period. Its introduction promises telephone contact and a proposed handling opinion within four hours after a complaint. This is an initial response, not four-hour repair completion.

For urgent quality issues needing site work after contact, it states attendance within twenty-four hours in Jiangsu/Zhejiang/Shanghai and seventy-two hours outside that region. The page does not define an overseas service network or destination-specific travel arrangement. Non-manufacturing faults may incur travel/technical fees; damage outside the guarantee or caused by other factors is paid repair. Obtain written applicability, local support responsibility and parts/transport terms for the destination.

  1. Record warranty commencement

    Confirm dispatch-based dates and handling of transit, storage and commissioning periods.

    Read the source
  2. Separate response from resolution

    Clarify diagnosis, parts supply and repair arrangements beyond the promised initial contact.

    Read the source
  3. Confirm destination support

    Identify the actual service party, site attendance coverage, costs and exclusions for the delivery country.

Project gallery names are leads for verification, not operating results

The reviewed project index mostly uses the generic caption “case display”, with named listings for Jiujiang Zhonghui Century City and Wujiang First People’s Hospital. The index does not supply a model schedule, commissioning duty or verified present performance for those projects. No installation success rate or customer endorsement is inferred.

Ask for a comparable reference with permission to verify it, specifying fan family, selected duty, site layout and the acceptance record. For the new order, approve the fan curve/pressure basis, dimensions, port orientation, acoustic evidence and applicable conformity documents before releasing manufacture.

07 / TRANSPARENCY

Sources and review scope

Compiled by HVACDeck Editorial. Page review: 2026-10-11. Publications are attributed below; their statements are not independent measurements by this platform.

  1. Official introduction and service commitmentChecked 2026-10-11 · Location and dispatch-based warranty/response/geographic terms read; supplier commitment not measured delivery history.
  2. Official contact pageChecked 2026-10-11 · Published address and email reviewed; private CRM664 already has separate email/source fields, preserved.
  3. Official DBF/DSF detail and original table/code/port imagesChecked 2026-10-11 · Full text and four original images read; A/E configurations and DSF claim separated.
  4. Official management/test/explosion-document galleryChecked 2026-10-11 · Six actual images inspected: past management dates, SWF-13 report cover and BDWEX-900 certificate; no present DBF approval inferred.
  5. Official fire-certificate galleryChecked 2026-10-11 · Inspected attachment samples identify fire dampers; not all gallery pages authenticated or cabinet-fan certification.
  6. Original utility-model publication CN211550023UChecked 2026-10-11 · Original full text read; diagonal-flow subject, holder and publication dates; not DBF performance/current rights.
  7. Official project indexChecked 2026-10-11 · Index captions/names read; no model-specific operating or acceptance result established.
  8. Original DBF A-fan performance table imageChecked 2026-10-11 · Actual rows/units read; each example kept as a complete row, without rated-air/acoustic-test assumptions.
  9. Original DBF E-fan performance table and worked exampleChecked 2026-10-11 · Actual row values read; residual/total-pressure and Y-position wording discrepancies retained.
  10. Original twelve-position inlet/outlet diagramChecked 2026-10-11 · Actual twelve numbered orientations inspected; no selected cabinet dimensions inferred.
  11. Original model-code diagramChecked 2026-10-11 · Direct/belt and shaft codes read; Y right-side conflicts with the worked example.

How we review sources · Represent this factory or request a correction

Continue your equipment research

Prepare your equipment brief