MANUFACTURER / SOURCE REVIEW

Bokaqi · Chuzhou heat-pump manufacturing and OEM supply

Bokaqi (Chuzhou) HVAC Energy-Saving Equipment Co., Ltd.

Commercial air-source heating/cooling, with separate whole-unit and component bases and model-specific selection data.

滁州市, 安徽省, China

Prepare a technical enquiry
1 published equipment referenceLatest source review 2026-10-11
01 / COMPANY

What this manufacturer offers

Bokaqi’s official Chinese site identifies 博卡崎(滁州)暖通节能设备有限公司 as the supplier behind its heating, hot-water and commercial air-source equipment. The company describes whole-unit manufacturing in Chuzhou and HVAC-component manufacturing in Wuhu, with OEM/ODM support. Its published contact address is in Quanjiao County, Chuzhou.

The commercial engineering catalogue contains four individually named YZDLR GXS models. Their winter and mild-weather heating figures differ substantially, so selecting a unit by the number in its name would obscure the stated rating conditions. This profile links to a separate product brief that preserves those conditions and identifies table entries requiring confirmation.

The Guangxi Refrigeration Society’s own enterprise-member directory separately lists the exact Chuzhou company under ordinary corporate members. That is evidence of the directory listing, not a plant audit, laboratory accreditation or approval of a particular heat pump.

Named supplier
博卡崎(滁州)暖通节能设备有限公司Official company/contact pages; match the quotation and invoice to this entity. Source
Published contact location
22 Wenhua Avenue, Shitan Modern Industrial Park, Shizi Town, Quanjiao County, Chuzhou, AnhuiContact-page address; not an independently audited manufacturing site. Source
Manufacturing organisation
Chuzhou whole units; Wuhu HVAC componentsSupplier’s description of two bases; ownership and order responsibilities need confirmation. Source
Reviewed commercial models
YZDLR-70GXS, -80GXS, -90GXS and -160GXSFour official product-detail pages, with separate cold-weather heating and cooling ratings. Source
Industry directory evidence
Ordinary corporate member listing, Guangxi Refrigeration SocietyExact Chinese company name observed on the society’s own member page; no product certification inferred. Source
02 / EQUIPMENT

Published equipment and selection evidence

Commercial air-source heating and cooling catalogue family
series REFERENCE

Commercial air-source heating and cooling catalogue family

Catalogue reference: Commercial engineering family

Open the equipment selection brief
Parameters and source limits · Commercial engineering family

Swipe the table, or focus it and use arrow keys, to read conditions and sources.

Manufacturer-published information · Commercial engineering family
ParameterPublished valueConditions and evidence
Electrical supply380 V, 3N, 50 HzPublished on each model page. Neutral, protective earth and final wiring schedule must follow the actual unit documentation. Source
RefrigerantR410aCommon published table entry; charge, circuit arrangement and destination documentation are not specified. Source
Cold-weather heating comparison42 / 52 / 60 / 108 kW70 / 80 / 90 / 160GXS respectively, at the page’s A−12/W41 condition; not capacity throughout the ambient envelope. Source
Published ambient envelope−35°C to 43°CListed on all four pages; no full output/defrost/water-temperature operating map was supplied. Source
Protection descriptionsClass I; IPX4Official model-table wording, not independently checked certification or a complete installation specification. Source
03 / PROJECT REVIEW

Review the Chuzhou supplier, then select a heat pump at the actual winter duty

Separate company age, experience and manufacturing responsibility

The homepage gives 27 March 2024 as the Chuzhou company’s establishment date, while the introduction describes more than twenty years in air-source technology. Its timeline also discusses earlier refrigeration activity and precision manufacturing. Those are different claims: accumulated business or staff experience is not the legal age of this particular supplier.

For an OEM order, ask which entity contracts, which base assembles the heat pump and which party supplies coils, pipework and other components. The two-base description does not independently establish ownership, transfer of qualifications or the scope of a Wuhu company’s certifications. Keep the manufacturer, brand owner and service provider named in the order records.

OEM/ODM covers more than changing the front-panel brand

The supplier offers OEM/ODM solutions alongside heat pumps and related evaporators, condensers, copper/aluminium pipework and packaging. A heat-pump private-label order needs its own approved technical and responsibility schedule. The reviewed photograph carries Yangzi branding; it is a catalogue illustration, not a guarantee that every Bokaqi configuration has the same brand, compressor, controller or certification.

Complete commercial unit

Agree the exact model/revision, refrigerant, selected winter and cooling duties, controller, electrical supply, water connections and included accessories.

Private-label configuration

Agree artwork/nameplate, manuals, destination documentation, parts traceability and who is responsible for changes to the tested configuration.

Component supply

For coils or pipework, issue a separate drawing, material and inspection brief. Whole-unit performance figures do not describe an individual component.

Read laboratory claims within their demonstrated scope

The company describes an enthalpy laboratory with a −45°C to 43°C range, along with noise and material-testing facilities. An official image visibly labels an enthalpy laboratory; the reviewed campus image is an architectural rendering. These images do not establish current laboratory accreditation, measured throughput or completion of a site inspection.

The laboratory range is not the operating range of every heat pump. The reviewed GXS tables separately state −35°C to 43°C, without a full output curve across that envelope. Request the actual unit’s test report and its operating limits at the required water temperature. The website’s ISO9001/ISO14001 and occupational-management wording has not been matched here to current issuer records, covered entity/site and expiry dates.

Manufacturing evidence

Request a current process/inspection plan for the supplying base and configuration, rather than relying on a campus rendering.

Read the source

Performance evidence

Request model-specific results, methods and operating conditions. A laboratory image or temperature range is not a test report.

Read the source

External directory evidence

The society’s exact-name listing supports its membership-directory presence only; it does not verify the advertised laboratory or output.

Read the source

Keep an award claim separate from GXS certification

The supplier’s 20 March 2025 article reports an HPE innovation-product award for a low-temperature inverter air-source heat-pump/chiller in the Yuexiang series. The reviewed article does not identify the four commercial GXS models as the awarded configuration, and no organiser-issued award record was established in this review. It is retained as a dated supplier announcement, not an independent rating or compliance certificate for the order.

Plan support around the destination and commissioning scope

The company describes a 2,000-plus service network, but the reviewed pages do not define coverage for an overseas project, a fixed warranty duration or response/repair deadlines. Its contact page provides telephone channels but no visible official email address; no email has been invented for the CRM.

For a commercial project, settle water-system commissioning, controls integration, frost protection and spare-parts support before signing. Have the supplier identify the service party at the destination and define which works or operating conditions affect coverage.

  1. Approve the duty and configuration

    Specify the design outdoor temperature, required water temperatures, heating/cooling loads and operating schedule; obtain a selected-model schedule.

  2. Approve manufacturing and documents

    Confirm the legal entity/base, configuration revision, test and destination documents, nameplate and handover materials.

  3. Approve the service agreement

    Record warranty start/coverage/exclusions, commissioning responsibilities, local support route and spare-parts availability in writing.

07 / TRANSPARENCY

Sources and review scope

Compiled by HVACDeck Editorial. Page review: 2026-10-11. Publications are attributed below; their statements are not independent measurements by this platform.

  1. Bokaqi official company introduction and facility imagesChecked 2026-10-11 · Chinese full text read; enthalpy-lab photograph and campus rendering visually inspected. Capability/certification statements remain supplier claims.
  2. Bokaqi official contact pageChecked 2026-10-11 · Named Chuzhou company and contact address; no visible official email identified.
  3. Official commercial low-temperature modular catalogueChecked 2026-10-11 · Four linked product detail tables individually read; linked product brief records conditions and unresolved entries.
  4. Guangxi Refrigeration Society — enterprise membersChecked 2026-10-11 · Original society directory full text read; exact Chuzhou company under ordinary corporate members. Directory listing only.
  5. Official dated HPE award announcementChecked 2026-10-11 · 20 March 2025 supplier article names Yuexiang series; no organiser confirmation or GXS model linkage inferred.
  6. Bokaqi official homepageChecked 2026-10-11 · Published establishment-date claim distinguished from corporate experience and earlier timeline; not an original registry verification.
  7. Bokaqi official YZDLR-70GXS table and photographChecked 2026-10-11 · Full original table and product photograph read; common ranges are cross-checked against all four pages.
  8. Bokaqi official YZDLR-80GXS tableChecked 2026-10-11 · All three rating conditions, paired inputs, water/electrical and dimensional entries read.
  9. Bokaqi official YZDLR-90GXS tableChecked 2026-10-11 · 72.6 kW / 152.7 A maximum and 22.4 m³/h retained as published, explicitly requiring confirmation.
  10. Bokaqi official YZDLR-160GXS tableChecked 2026-10-11 · Distinct ratings/size/weight; duplicated maximum electrical/water entries not used to correct another model.
  11. Original national-standard record — GB/T25127.1-2020Checked 2026-10-11 · Issuer record read for current status and industrial/commercial low-ambient scope only; no model conformity inferred.

How we review sources · Represent this factory or request a correction