01 / COMPANY

What this manufacturer offers

Shanghai Guandai Ventilation Energy Saving Equipment Co., Ltd. sells industrial fans under the Northing (锘森) brand. It offers standard commercial and HVAC fans and custom heavy industrial equipment for dust extraction, paper machinery, boilers and chemical processing. The catalogue lists light and heavy turbo blowers, low-flow high-pressure blowers, open and closed ultra-high-pressure arrangements and backward-curved high-pressure fans.

Across its whole offer, Guandai quotes 0.55–1,000 kW equipment, 250–2,500 mm impellers, static pressure up to 30,000 Pa and high-temperature capability above 800°C. Each figure describes the edge of a different product group. A quoted blower gets its own rating from the selection.

The light-duty turbo-blower page, dated 23 October 2019, has an empty model field. Its text covers centrifugal-blower construction and vibration maintenance and has no selection table. Public records add a 2024 high-tech-enterprise listing and a 2024 occupational-health warning. For an order, ask for the selected model sheet, curve and factory test plan.

Industrial-fan brand
Northing / 锘森Brand named on Guandai's company page. Ask for the trademark registration if brand ownership matters. Source
Light-duty blower page
Light-duty turbo blower; model field blank; updated 2019-10-23A family and maintenance page without a model selection. Source
Government list entry
2024 second-batch high-tech certificate collection list · GR202431003885Fengxian list, row 100, PDF page 5. A company-level recognition. Source
02 / EQUIPMENT

Published equipment and selection data

Light-duty turbo blowers
series REFERENCE

Light-duty turbo blowers

Catalogue reference: Light-duty turbo blowers

Open the equipment selection brief
Parameters and source limits · Light-duty turbo blowers

Swipe the table, or focus it and use arrow keys, to read conditions and sources.

Manufacturer-published information · Light-duty turbo blowers
ParameterPublished valueConditions and sources
Published itemLight-duty turbo-blower family · model field blankPublished 2019-10-23 with no designation or performance table. Source
Construction describedImpeller, diffuser and voluteThe selected drawing gives the number of stages and materials. Source
Drive shownMotor, shaft/coupling region and common baseAsk for the coupling, bearing and seal details of the offered unit. Source
Performance curveNot published for this itemRequest the curve for the selected machine at your gas conditions. Source
Company range0.55–1,000 kW; 250–2,500 mm impellers; up to 30,000 Pa staticLimits of Guandai's whole fan offer, each from different products. Source
03 / ORDERING

Northing Guandai industrial fans and turbo blowers: range, selection and records

Company limits and a selected blower

Guandai's introduction gives power, diameter, pressure and temperature figures for its whole fan offer. The light-duty page has no selection record that brings those limits together in one machine, so each quoted blower needs its own operating envelope.

Company-wide range

Equipment from 0.55 to 1,000 kW, impellers from 250 to 2,500 mm, pressure up to 30,000 Pa and high-temperature capability above 800°C, each describing a different part of the offer.

Read the source

Light-duty selection to request

Full model designation, curve, speed, absorbed power, motor and handled-gas conditions for the quoted unit. The page has no numerical table to read these from.

Read the source

Construction and vibration maintenance

Guandai describes a turbo blower as a centrifugal machine with impeller, diffuser and volute. The page then covers alignment, corrosion inspection, dynamic balancing and vibration monitoring, and mentions a 2120 data collector. Ask whether the quoted light-duty machine uses the same bearings, drive and monitoring equipment.

The page gives a percentage for faults caused by misalignment with no study behind it, and suggests nitrogen preservation in storage. Ask for the operation and maintenance manual of the selected machine and Guandai's own commissioning requirements, and follow those.

For vibration, agree the coupling between motor and blower, the mounting foundation, the bearing system, the measuring points and the acceptance limits for the configuration you are buying.

Custom process fans: state the gas first

Guandai designs custom heavy industrial fans for process and commercial duties. A boiler or dust-extraction enquiry differs from an HVAC ventilation request, and the light-duty blower's materials and temperature limits are not on its page.

  1. Describe the process stream

    Give gas composition, temperature, density basis and any dust or corrosive content, and say whether the fan moves clean air or process gas.

  2. Ask for the selected design

    Ask Guandai for the blower family, inlet arrangement, materials, drive and speed for that duty, and compare airflow, pressure and power at the same conditions.

  3. Agree the acceptance basis

    Attach the drawing, performance documents and vibration and commissioning basis to the quote. Name who installs, aligns and commissions the machine at your site.

Two public records

The 14-page Fengxian high-tech-enterprise certificate collection list names Shanghai Guandai on page 5, row 100, with certificate GR202431003885 in the 2024 second batch. A Fengxian Health Commission notice records a warning issued to the company.

High-tech enterprise recognition

The exact company name and GR202431003885 appear on the government-hosted list. It is a company recognition and sits apart from product conformity or a duty rating.

Read the source

Occupational-health warning

A warning dated 25 December 2024, decision 奉第2120244615号, for failing to guide and supervise workers' personal occupational-disease protection. The notice says nothing about later remediation or blower performance; ask Guandai how it was resolved.

Read the source

Where Guandai stands for a buyer

Guandai offers custom-designed industrial fans, a broad family catalogue and a dated high-tech recognition. A light-duty blower order still needs a selection, and factory capacity is best seen in person.

Ask for a current model sheet and curve, an arrangement drawing, the operation and maintenance manual and a clear supply and commissioning boundary. If the company's recognition or working conditions matter to you, check their present state. Guandai mentions overseas markets; ask about local service staff, spare parts and response times in your country.

Confirm in writing before ordering

Get Guandai's written confirmation of: the blower model and its curve at your gas conditions; speed, absorbed power and motor; materials and temperature limit; bearing, coupling and vibration acceptance values; the operation and maintenance manual; who commissions the machine; and how the December 2024 warning was closed.

07 / SOURCES

Sources

Compiled by HVACDeck Editorial. Updated 2026-11-06. Each fact on this page comes from the publication listed below.

  1. Guandai company introductionChecked 2026-10-07 · Northing brand, standard and custom offer, and company-wide range figures.
  2. Light-duty turbo-blower pageChecked 2026-10-07 · Updated 2019-10-23: blank model field, construction and vibration maintenance text.
  3. Fengxian 2024 second-batch high-tech certificate listChecked 2026-10-07 · Page 5, row 100: company name and GR202431003885.
  4. Fengxian occupational-health decision noticeChecked 2026-10-07 · Published 2024-12-31; warning decision dated 2024-12-25 and its grounds.

How we compile profiles · Represent this factory or request a correction

Related equipment and guides

Prepare your equipment brief