Bigfans Airova Max commercial ceiling fans

Approve fan and lighting interfaces against the actual commercial room; perceived comfort claims are not refrigeration or a lighting design.

From Bigfans Wuhan · Large-space air-movement equipment

Individual product research · HVACDeck Editorial · Sources checked 2026-10-11

Bigfans Airova Max commercial ceiling fans
Manufacturer catalogue image · AM25 / AM30 / AM36
01 / UNDERSTAND THE EQUIPMENT

Coordinate commercial circulation, light and ceiling fit

Bigfans’ Airova Max is a commercial ceiling-fan family offered for restaurants, gyms, libraries and lobby spaces, with integrated-light wording and three diameters from 2.5 to 3.6 m. Its original commercial-scene artwork illustrates appearance rather than an independently verified installation. AM36 lists 3.6 m, 95 rpm, 48 kg and 0.4 kW motor power; the page supplies no lighting output, exact included light configuration or issued mounting-envelope drawing.

The source describes 6063-T5 alloy blades and promotes perceived cooling of 3–8°C, but that is not a measured reduction in room air temperature. The generic 50 rpm comfort claim is separate from maximum-speed rows of 95–130 rpm. Obtain real occupied-zone air-speed, sound and electrical schedules for the intended ceiling and furniture layout before approving commercial comfort or lighting. No independently demonstrated savings, uniform temperature decrease or universal low-ceiling fit is established.

02 / READ THE CONDITIONS

Published parameters and their scope

This is an equipment family; its range does not identify one orderable configuration.

Family designation
AM25 / AM30 / AM36

Swipe the table, or focus it and use arrow keys, to read the conditions and sources.

Manufacturer-published values · conditions are part of the specification
ParameterPublished valueConditions and evidence
AM36 source row3.6 m; 95 rpm maximum; 48 kg; 0.4 kW motorNo complete controller/light consumption or mounting envelope supplied. Source
AM25/30 choices2.5/3.0 m; 130/110 rpm; 41/44 kg; 0.26/0.35 kWDiameter alternatives within one commercial series. Source
Flow/current referencesAM36 6,750 m³/min; 1.3 A / 220 VFlow method, phase and motor/controller input boundaries unprovided. Source
Construction statement6063-T5 alloy blades; integrated-light descriptionNo material certificate, optical output or exact ordered light BOM reviewed. Source
Comfort claim boundary1–3 m/s and perceived cooling 3–8°C advertisedNo reviewed measurement map, occupant conditions or room-temperature reduction test. Source

Selection and application review

Specify circulation and comfort at the actual seating/work zones

Issue room dimensions, ceiling/support height, furniture, occupied positions and preferred air-speed range. Obtain a selected layout and measured or agreed delivery criteria. Catalogue circulation volume does not establish outdoor-air ventilation or exhaust of cooking contaminants.

Keep perceived cooling separate from refrigeration. The 3–8°C wording has no reviewed occupant, humidity or test definition and cannot be used to subtract a fixed amount from air temperature. Compare speed, delivered air and sound at actual occupancy rather than selecting by a comfort slogan.

Approve the combined ceiling and lighting arrangement

Obtain selected mounting loads, drop, blade/service clearances and retention instructions from an issued drawing. Low-ceiling suitability is described without numerical geometry. Do not transfer a larger industrial family’s diagram as approved AM mounting data.

If light is ordered, request included module, output/distribution, colour/control and electrical schedule. The scene illustration and integrated-light phrase do not establish illuminance at tables or a complete lighting design. Agree what the supplier, ceiling contractor and electrical installer provide.

Close motor, acoustics and current before comparing operating cost

Obtain complete input, phase/startup and controller specification for the selected 220 V configuration. Motor kW and a full-load current entry have undefined input/output boundaries; they are not a verified whole-system energy schedule. Material-grade wording and surface finish do not provide a complete durability report.

Request sound data with its quantity, speed, method and receiver conditions. General quietness and a 50 rpm narrative do not establish a numerical maximum-sound result at the table’s maximum speed. No fixed operating-cost saving is computed here.

Accept the selected commercial package

Approve the current model/BOM, ceiling/retention drawing and separately specified light/controller options. Verify actual occupied-zone delivery, speed/control behaviour, electrical functions and agreed sound/lighting criteria. Identify cleaning, inspection and service access in the finished interior.

Price, delivery and independent installation or comfort results remain unknown. All three diameters stay on one page; original supplier scene artwork is labelled as illustration rather than a proven customer reference.

  1. Define room delivery

    Approve actual occupied-zone air speed and comfort criteria.

  2. Freeze ceiling and light

    Obtain current mounts, complete light/BOM and electrical scope.

  3. Verify installed functions

    Check controls, delivery, sound and separately specified lighting.

Sources and review scope

Compiled by HVACDeck Editorial. Source review identifies what the publication states; it is not an independent performance test or certification.

  1. Official Airova Max familyChecked 2026-10-11 · Complete commercial narrative and three-model table read; unconditioned comfort/material/light statements retained within scope.
  2. Original commercial scene illustrationChecked 2026-10-11 · Supplier artwork visually inspected; no independently verified project or exact light performance established.

Editorial method and corrections · Report a detail with this page URL

Turn the evidence into an enquiry

Send the manufacturer your required duty, installation conditions and the unresolved items identified in this brief.

Continue the selection

Other equipment from this manufacturer

Bigfans Fengchi BFFCA industrial ceiling fans

Bigfans Airova Pro AP commercial ceiling fans

Bigfans P column-supported large-space fans

Bigfans Fengzhi WF directional wall/suspended fans

Bigfans XM mobile floor circulation fans

Bigfans Fengrui SFFCA PMSM ceiling fans