Bigfans XM mobile floor circulation fans
Approve a heavy wheeled assembly and its cable/air path; resolve the small-model power-unit conflict before comparing consumption.
From Bigfans Wuhan · Large-space air-movement equipment
Individual product research · HVACDeck Editorial · Sources checked 2026-10-11
Bring directed circulation to a defined temporary work zone
Bigfans’ XM mobile family is a guarded floor fan on a wheeled frame, intended to direct circulation where a fixed ceiling installation is unsuitable. XM15 and XM20 are listed at 1.5 and 2.0 m diameter with masses of 140 and 172 kg, making handling, floor space and cable routes important purchase decisions. The original image shows a guarded wheel and castors but supplies no brake specification, transport procedure or complete stability assessment.
The source lists XM20 motor power as 0.5 kW, while XM15 is printed as 0.5 W. That unit conflict must be resolved before approving an electrical budget; it is not silently corrected here. Claimed effective coverage near 300 m² and perceptible air beyond 30 m have no reviewed velocity map or test conditions. Select the unit against an actual working zone and obtain its current electrical, movement and guarding instructions.
Published parameters and their scope
This is an equipment family; its range does not identify one orderable configuration.
- Family designation
- XM15 / XM20
Swipe the table, or focus it and use arrow keys, to read the conditions and sources.
| Parameter | Published value | Conditions and evidence |
|---|---|---|
| XM20 reference | 2.0 m; 280 rpm; 172 kg; 0.5 kW motor | Source family table; no complete footprint, brake or transport schedule. Source |
| XM15 source conflict | 1.5 m; 300 rpm; 140 kg; motor row 0.5 W | Do not silently rewrite as 0.5 kW; obtain corrected current schedule. Source |
| Flow/current rows | XM15/20 1,588/2,355 m³/min; both 1.8 A / 220 V | No airflow test basis, phase or complete controller demand supplied. Source |
| Promoted reach | Approximately 300 m² coverage; sensation beyond 30 m | Supplier claims without specified occupied-zone velocity or obstacles. Source |
| Original arrangement | Guarded wheel, lower frame and castors | Image inspected; wheel-locking, clearance and stability limits unprovided. Source |
Selection and application review
Map the directed airflow to the occupied zone
Issue working positions, aisles, obstacles and the intended fan direction. Obtain measured or selected air speeds at the required distances, rather than using 300 m² as a universal coverage guarantee. Define comfort without treating circulation as fresh-air exchange or a refrigeration load.
If a process generates contaminants, select extraction/ventilation separately. The source supplies no filter, contaminant removal or outdoor-air duty. Arrange the unit through an approved site assessment instead of assuming more airflow solves every work-zone problem.
Approve movement and floor restraint for the actual mass
At 140–172 kg, the assembly is a handled industrial unit, not an assumed hand-carried appliance. Obtain castor/brake, stability, permissible surface/slope and movement instructions. The photograph does not prove how it is locked or moved safely in the customer’s aisle.
Close footprint, access and guarding with the current assembly drawing. Define who relocates it and how the electrical connection is isolated and protected during movement. No universal clearance or stability limit is invented from the family image.
Resolve the power row and temporary electrical connection
Request written confirmation of XM15’s 0.5 W entry and the selected motor/controller schedule. Both rows share a 1.8 A / 220 V reference but no phase/startup or full operating-input definition. Do not convert an ambiguous motor entry into a verified consumption or energy-saving figure.
Obtain cable, protective, control and environmental requirements for the actual work area. The page supplies no whole-assembly ingress or hazardous-area rating. PMSM and gear-free language does not establish universal electrical suitability or zero maintenance.
Accept one mobile configuration and its service instructions
Approve the current model, guarding, movement/locking procedure and electrical documents. Verify direction/speed, controls, restraint and actual occupied-zone delivery at the agreed operating range. Record how the guard/wheel can be cleaned and inspected without guessing a lubrication interval.
Supplier reliability and maintenance-free adjectives are not independently tested life guarantees. Price, delivery and a measured 300 m²/30 m performance map remain unknown. Both diameters remain in this one practical mobile-family page.
Define the temporary zone
Agree required air speed, location and obstacles.
Approve handling and power
Resolve restraint, cable route and XM15 power-unit question.
Verify installed use
Test delivery, controls, guards and movement instructions.
Sources and review scope
Compiled by HVACDeck Editorial. Source review identifies what the publication states; it is not an independent performance test or certification.
- Official XM familyChecked 2026-10-11 · Full two-model table and reach claims read; 0.5 W/0.5 kW mismatch retained.
- Original mobile-family imageChecked 2026-10-11 · Guard/frame/castors inspected; exact brake and transport specification not supplied.
Editorial method and corrections · Report a detail with this page URL
Turn the evidence into an enquiry
Send the manufacturer your required duty, installation conditions and the unresolved items identified in this brief.
Continue the selection