5 published equipment referencesLatest source review 2026-10-11
01 / COMPANY
What this manufacturer offers
Hebei Langri Heating and Cooling Equipment Co., Ltd., legally 河北朗日冷暖设备有限公司, manufactures room-side fan-coil equipment and offers air-source heating/cooling units from Nanwangzhuang, Donglü, Qingyuan District, Baoding. The preserved CRM export matches the official displayed business licence on the legal name, 14 June 2017 establishment, credit code 91130608MA08NA4W4K and village address. The displayed licence carries an April 2024 issue date. The website uses the 筑立方 / ZHULIFANG wordmark; that brand display does not replace the contracting entity.
The useful manufacturing evidence is specific: supplier-hosted original photographs show fan-coil assembly, electrical terminal work, copper headers/coils and a station labelled pressure testing. The product gallery distinguishes concealed horizontal, wall, exposed console/ceiling and cassette forms. Its performance disclosure is much weaker: most detail pages supply images and a one-line service statement rather than model rating tables. This assessment separates those observed constructions from missing thermal, acoustic and hydraulic evidence, and reads the government and certificate records within their dates and exact scope.
Matched legal identity
河北朗日冷暖设备有限公司; established 14 June 2017CRM and displayed business licence agree; dated licence image rather than a current registry extract. Source
Registered/contact location
Nanwangzhuang, Donglü, Qingyuan District, Baoding, HebeiOfficial contact, company description and displayed licence use the same locality. Source
Displayed brand
筑立方 / ZHULIFANGOriginal website logo visually reviewed; no independent trademark-rights search performed. Source
Observed manufacture photographs
Fan-coil assembly, electrical wiring, copper coil/header work and pressure-test stationActual supplier-hosted originals inspected; no visit, throughput or calibration audit. Source
Government list record
2025 proposed subsidy list: GR202313003778, row 56Hebei industry department PDF, physical page 4; notice was a proposal for public comment, not proof of payment. Source
Displayed CRAA scope
Fan-coil units; FP series; GB/T 17758-2010Original certificate shows validity to March 2027; current issuer status and ordered-model coverage not checked. Source
Displayed heat-pump CCC documents
Two displayed certificates expired 9 May 2025Original certificate images read. Historical documentation, not a current blanket CCC badge. Source
Parameters and source limits · Ultra-thin concealed horizontal family
Swipe the table, or focus it and use arrow keys, to read conditions and sources.
Manufacturer-published information · Ultra-thin concealed horizontal family
Parameter
Published value
Conditions and evidence
Official construction name
Ultra-thin concealed horizontal fan coil
Original Chinese title; no dimensioned height or model-specific clearance given. Source
Visible original arrangement
Rectangular metal casing, finned opening, mounting tabs and end connections
Original images inspected; connection sizes, handed configuration and included accessories unknown. Source
Published thermal schedule
Not supplied on the reviewed detail page
No cooling/heating kW, air/water conditions, flow or pressure drop may be inferred from the photograph. Source
Family consolidation
Four views of the same concealed construction
Appearance and photographic angle do not create separate model pages. Source
Certificate boundary
Company’s displayed CRAA fan-coil FP-series scope
Selected concealed model correspondence and current issuer status require confirmation. Source
03 / PROJECT REVIEW
Assess fabrication evidence before choosing a room terminal
What the production gallery actually shows
The assembly image shows rows of room terminals and cassette housings at workbenches, with personnel wearing the displayed brand. Other originals show a worker connecting an electrical terminal strip, copper header/coil work and a station labelled pressure testing. These are stronger evidence of the claimed fan-coil operation than the generic skyscraper image on the company page. They do not establish current output, automated-line capacity or the quality of a particular shipment.
For a factory review, request a walk-through tied to the selected construction: coil fabrication or purchased-coil responsibility, connection/joint work, pressure/leak procedure, electrical safety checks and packing. Ask for the actual test record and traceability for the ordered batch. A photographed pressure-test station alone cannot establish its pressure, medium, acceptance threshold or calibration.
Compare terminals by their installation problem
The concealed horizontal unit exposes a finned coil opening, end connections and mounting tabs; it needs an issued ceiling/duct/service arrangement. The wall water-air-conditioner looks superficially like a refrigerant split indoor head, but the official category is hydronic wall equipment. Exposed consoles and ceiling units avoid the same concealment arrangement but require their own support and drain drawings. Cassette images show a central grille with perimeter discharge slots, including the named dual-outlet construction.
The website also lists several curved-shell and side-outlet styles. Those are not separate performance classes merely because they have separate pictures. This directory consolidates cosmetic alternatives and nominal size labels. Select against the room duty, pipe circuit, acoustic requirement and actual service access rather than counting gallery tiles.
Certificates need a model, a date and a current status
The displayed CRAA certificate identifies fan-coil equipment, an FP-series scope and GB/T 17758-2010. Its printed dates extend to March 2027, but the platform has not established present issuer status or that a particular pictured terminal belongs to that schedule. Obtain the complete current annex and selected-model correspondence before using it in a procurement dossier.
Two supplier-hosted CCC originals for heat-pump heating/cooling units show issue date 9 May 2020 and expiry 9 May 2025. Their printed R410A and electrical/model details apply to those historical schedules, not automatically to a 3P gallery picture or every current offer. No current CCC claim is inferred. General management-system statements and commercial credit plaques are also not equivalent to ordered-product conformity.
Use the government record as a dated identity cross-check
The Hebei industry-and-information department’s June 2025 document is headed a list of high-tech enterprises proposed for subsidy. The notice specifies public comment from 19 to 23 June 2025. Physical page 4, row 56 identifies this exact company with GR202313003778 in Baoding. That is evidence of inclusion in the proposed list; it is not a payment receipt, a new product certificate or an independently measured efficiency result.
The enterprise description claims a low-temperature enthalpy laboratory down to −35°C. No reviewed laboratory report demonstrates a particular ordered heat pump’s capacity, COP or frost behaviour at that temperature. Keep the laboratory claim and the product operating envelope separate.
Turn the enquiry into an auditable selection
The product details rarely publish a complete rated thermal schedule. Ask for sensible/total cooling and heating at stated water/air conditions, flow and pressure drop, fan speed, input and sound basis, dimensions and connection/drain locations. The heat-pump P labels cannot substitute for kW output at the required outdoor/water conditions.
The home page advertises a six-year warranty and 24-hour response; obtain the actual contract terms, region, exclusions and labour responsibility rather than treating them as platform guarantees. The official email is held separately in private CRM for a later authorised claim process. This is a platform-written document review, not a factory visit or product test.
Choose the construction
Set room duty, mounting, hydraulic circuit and service access before comparing shell styles.
Request the selected schedule
Obtain thermal, sound, hydraulic and electrical data at the actual conditions.
Verify scope and delivery
Match certificates, production tests, approved drawings and warranty terms to the exact order.
07 / TRANSPARENCY
Sources and review scope
Compiled by HVACDeck Editorial. Page review: 2026-10-11. Publications are attributed below; their statements are not independent measurements by this platform.
Official certificate galleryChecked 2026-10-11 · Original CRAA and both CCC images inspected. Printed expiry and product scope bounded; issuer status not checked.
Official dual-outlet cassette pageChecked 2026-10-11 · Complete text and original panel image reviewed; other cassette recommendations observed and consolidated, not individually rated from outlet names.
Official 静弧 wall-terminal pageChecked 2026-10-11 · Full body and original front illustrations reviewed; category identifies water air conditioning, but no selected rating table.
Official wall-category style referenceChecked 2026-10-11 · Observed same-category curved-shell reference; differences in rated internals not established, consolidated without separate URL.