MANUFACTURER / SOURCE REVIEW

Xinwuxin · Wuhan process-refrigeration equipment

Match a documented Wuhan manufacturing identity to the cooling circuit, ice-handling package and actual project delivery responsibility.

Wuhan, Hubei, China

Prepare a technical enquiry
7 published equipment referencesLatest source review 2026-10-11
01 / COMPANY

What this manufacturer offers

Wuhan Xinwuxin Refrigeration Equipment Co., Ltd., legally 武汉新武新制冷设备有限公司, supplies assembled refrigeration equipment and project cooling systems from Yangluo, Wuhan. The preserved CRM record and the original business-licence image displayed by its official website agree on 16 March 2005, credit code 91420105771387151E and the C-F10 address in Huazhong International Industrial Park. The displayed licence was issued on 17 May 2022. It is a dated identity document, not a fresh live registry check or a pressure-vessel manufacturing approval.

The individually reviewed catalogue distinguishes twin-screw liquid chillers, integrated heat-rejection packages, flake-ice machines, container ice storage/conveying systems, parallel compressor racks, air-cooled screw chillers and geared centrifugal packages. The distinctions concern what is assembled, where heat is rejected and how cooling or ice reaches the process. The website describes concrete temperature control, distillery cooling, chemical and pharmaceutical applications. This profile evaluates those offers and their evidence boundaries; no factory visit, throughput audit or customer acceptance test has been conducted by the platform.

Matched establishment and identity
16 March 2005; 武汉新武新制冷设备有限公司CRM agrees with the original displayed business licence, issued 17 May 2022. Source
Matched registered/contact location
Huazhong International Industrial Park, Yangluo, Wuhan; C-F10Official contact and displayed licence agree; no independent current workshop inspection. Source
Manufacturing scope in displayed licence
Refrigeration/air-conditioning equipment and industrial automatic-control equipmentGeneral manufacturing scope expressly excludes special-equipment manufacturing; not a vessel-production licence. Source
Actual equipment portfolio
Liquid chillers, ice machines/storage, parallel racks and centrifugal packagesIndividual product bodies and original diagrams reviewed; not every website menu link identifies the right product. Source
Government record
2023 Hubei high-tech enterprise list: GR202342007276; 8 December 2023Exact company row 7276, PDF physical page 176. Dated recognition, not current product certification. Source
Project cooling applications
Concrete temperature control, distillery and chemical/pharmaceutical process coolingSupplier descriptions; independently verified delivery, measured results and service response unknown. Source
02 / EQUIPMENT

Published equipment and selection evidence

Parameters and source limits · YDLSRTBMS

Swipe the table, or focus it and use arrow keys, to read conditions and sources.

Manufacturer-published information · YDLSRTBMS
ParameterPublished valueConditions and evidence
Published compressor constructionSingle-stage geared centrifugal; semi-hermetic motorSupplier narrative; actual compressor maker/model and issued mechanical schedule required. Source
Capacity-control descriptionInlet guide vanes and movable diffuser; supplier states 10–100% regulationSupplier claimed operating range, not an independently established surge-free map. Source
Illustrative model rowYDLSRTBMS500.1: 1758 kW cooling / 301 kW input; COP 5.8Original table; simultaneous thermal conditions and input-package boundary absent. Source
Illustrative circuit flowsYDLSRTBMS500.1: 302 m³/h chilled / 354 m³/h cooling waterOriginal labelled table flows; entering/leaving temperatures are not provided for final hydraulic/thermal selection. Source
Illustrative equipment/operating massYDLSRTBMS500.1: 14800 / 17020 kgOriginal table; actual shipping splits, support loads and filled boundary must be issued. Source
Emergency oil-supply descriptionBackup oil cylinder and oil-return arrangementSupplier describes oil-supported stop during pump fault or power loss; actual test and endurance boundary unverified. Source
Low-voltage starting leadOnboard soft-start cabinetSupplier series statement; actual voltage, full-load current and protective schedule require confirmation. Source
Xinwuxin air-cooled screw chillers · Ambient and circuit selection
series REFERENCE

Xinwuxin air-cooled screw chillers · Ambient and circuit selection

Catalogue reference: Air-cooled screw family; model rows 100–1530

Open the equipment selection brief
Parameters and source limits · Air-cooled screw family; model rows 100–1530

Swipe the table, or focus it and use arrow keys, to read conditions and sources.

Manufacturer-published information · Air-cooled screw family; model rows 100–1530
ParameterPublished valueConditions and evidence
Published heat-exchanger arrangementFinned air-side exchanger; shell-and-tube evaporatorOriginal table construction rows and family illustration reviewed. Source
Narrative circuit arrangementOne or two compressors; independent circuit for eachSupplier family alternative; actual circuit count and failure duty require a model selection. Source
Illustrative table rowModel 100 at 5°C evaporation: 84 kW cooling / 28 kW compressor inputSource row only; entering-air/condensing condition and total fan input are not supplied. Source
Same model at −10°C evaporationModel 100: 47 kW cooling / 25 kW compressor inputRefrigeration evaporation temperature, not a guaranteed water-outlet selection. Source
Separate water-flow exampleModel 100: 14 m³/h in the 7°C outlet row; water resistance <80 kPaOriginal row; matching inlet temperature and simultaneous load conditions absent. Source
Source refrigerant discrepancyNarrative R134a; table R134a / R22 / R404 / R507 alternativesExact ordered refrigerant and current compressor compatibility must be issued. Source
Published controls claimsLoading/run-time coordination; electronic expansion valve; outlet control to 0.5°CSupplier claims without a reviewed test boundary or independently measured stability. Source
Xinwuxin parallel screw packages · Compressor and oil-system scope
series REFERENCE

Xinwuxin parallel screw packages · Compressor and oil-system scope

Catalogue reference: Parallel screw package; selected construction unresolved

Open the equipment selection brief
Parameters and source limits · Parallel screw package; selected construction unresolved

Swipe the table, or focus it and use arrow keys, to read conditions and sources.

Manufacturer-published information · Parallel screw package; selected construction unresolved
ParameterPublished valueConditions and evidence
Narrative single-stage envelope80–600 HP; evaporation 5 to −45°CSupplier prose, not a simultaneous performance map or chilled-fluid outlet range. Source
Narrative two-stage envelope100–600 HP; evaporation −30 to −65°CSupplier prose; reviewed tables do not establish rated duty down to −65°C. Source
Model-table example at −10°C evaporation160.2: 194 kW nominal refrigeration / 58 kW compressor inputOriginal first table; condensing condition and complete auxiliary-input boundary are not provided. Source
Same model at −20°C evaporation160.2: 134 kW nominal refrigeration / 52 kW compressor inputSame source model, different evaporating point; not a fluid-outlet-temperature selection. Source
Published architecture conflictBody: open single screw / Tables: semi-hermetic twin screwUnresolved source inconsistency; exact compressor make/model and construction required. Source
Oil arrangement descriptionHorizontal three-stage separation; selected dual oil filters and pre-lubrication pumpSupplier narrative; not every model confirmed to include the optional components. Source
Control and electrical leadModbus; tables state 380 V / 3N / 50 Hz and star-delta startingTable versus narrative controller details must be reconciled for the actual rack. Source
Parameters and source limits · XIL MS

Swipe the table, or focus it and use arrow keys, to read conditions and sources.

Manufacturer-published information · XIL MS
ParameterPublished valueConditions and evidence
Documented system functionsFlake-ice generation + raked storage + screw conveyingSupplier body describes three functions; actual purchased package and throughput need confirmation. Source
XIL MS-10T published row10 t/day output; 10 t storage; 64 kW refrigeration; 66 kW inputOriginal table; matching ambient/water rating conditions and total-input boundary are absent on this page. Source
XIL MS-70T published row70 t/day output; 20 t storage; 417 kW refrigeration; 256 kW inputCatalogue values, not verified site output. Storage mass is distinct from daily production. Source
Storage temperature descriptionApproximately −10°CSupplier storage-air description, not ice-generator evaporation or a witnessed hold test. Source
Conveying descriptionSealed screw conveyance; supplier states up to 60° inclinationNo selected conveying rate, distance, drive duty or demonstrated geometry supplied. Source
Size and weight boundariesTable prints 6058/12192 mm lengths and 8591/9540 mm heightsPublished assembly dimensions need issued GA and transport/module confirmation; no guessed corrections. Source
Container certification statusSupplier claim onlyNo certificate number, holder/scope, structural plate or current transport approval independently verified. Source
Parameters and source limits · XIL

Swipe the table, or focus it and use arrow keys, to read conditions and sources.

Manufacturer-published information · XIL
ParameterPublished valueConditions and evidence
Stated production test conditions25°C ambient; 20°C entering waterAccompanies both original model-table images; no independent witnessed test. Source
Stated flake thickness1.6–2.3 mmSupplier family description; actual selected operating envelope needs confirmation. Source
XIL-5T example5 t/24 h ice; 32.5 kW refrigeration; 20.39 kW total inputOriginal row at the stated ambient/water conditions; not a promise at hotter site conditions. Source
XIL-10T example10 t/24 h ice; 65 kW refrigeration; 40.72 kW total inputOriginal second schedule; compressor input separately listed as 36.8 kW. Source
XIL-10T physical row3200 × 2050 × 1870 mm; 1980 kgOriginal unit-size and weight columns; shipping/operating boundary and final GA must be issued. Source
Published refrigeration conditions−28°C evaporation; 36°C condensationImage-table temperatures, distinct from ice, ambient or inlet-water temperatures. Source
Electrical and refrigerant alternativesSeveral three-phase 50/60 Hz supplies; R404A with listed alternativesAlternative order configurations, not one unit approved for all supplies or refrigerants. Source
Parameters and source limits · YDLSLGBMZ

Swipe the table, or focus it and use arrow keys, to read conditions and sources.

Manufacturer-published information · YDLSLGBMZ
ParameterPublished valueConditions and evidence
Two documented heat-rejection layoutsWater-cooled condenser / evaporative condenserOriginal supplier-labelled assembly illustrations; not an issued P&ID. Source
Published model exampleYDLSLGBMZ210.1: 224.1 kW cooling; 41.2 kW inputOriginal table values only. Simultaneous thermal rating conditions are absent from the reviewed page. Source
Example transport and operating massYDLSLGBMZ210.1: 7500 / 8625 kgSupplier table; dry/operating mass labels read. Final ordered shipping/lifting data required. Source
Example assembly sizeSingle-head group: 12000 × 2400 × 3400 mmShared table cell, not verified container standard, transport envelope or final ordered GA. Source
Published site access noteMore than 1 m operation/maintenance space around equipmentSupplier guidance, not a complete airflow, lifting or statutory clearance design. Source
DCS connection leadModbus RTU through RS485Supplier description; I/O list, register map and permitted command boundary not supplied. Source
Xinwuxin screw chillers · Water and secondary-fluid selection
series REFERENCE

Xinwuxin screw chillers · Water and secondary-fluid selection

Catalogue reference: LSLGBME / LSLGBMS; YC / YS alternatives

Open the equipment selection brief
Parameters and source limits · LSLGBME / LSLGBMS; YC / YS alternatives

Swipe the table, or focus it and use arrow keys, to read conditions and sources.

Manufacturer-published information · LSLGBME / LSLGBMS; YC / YS alternatives
ParameterPublished valueConditions and evidence
Compression and capacity controlTwin screw; staged 25 / 50 / 75 / 100% or continuous regulationSupplier alternatives, not confirmation that both schemes are fitted to every selected unit. Source
Published exchanger constructionFlooded evaporator; enhanced copper heat-transfer tubesSupplier description; issued tube/material and pressure schedules still needed. Source
Low-temperature fluid mappingYC: ethylene-glycol solution; YS: calcium-chloride solutionExact supplier footnote; concentration and material compatibility are not stated. Source
Evaporative example at −10°C outletJYC/YSLGBGE190.1: 105 kW cooling / 34 kW input; COP 3.06Published low-temperature row at −5/−10°C fluid, 35°C condensing, 380 V three-phase 50 Hz; supplier data, not a measured guarantee. Source
Water-cooled exampleLSLGBMS120.1: 112 kW cooling / 25 kW input; COP 4.44Single-head table; footnotes 7/5°C water and 32/37°C condenser water. Column consistency requires supplier confirmation. Source
Control integrationModbus RTU through RS485 to the customer DCSPublished protocol/interface only; register map, bus settings and remote-control permissions missing. Source
Unresolved rating boundary5/7°C vs 7/5°C; mixed condenser footnotes and questionable table cellsNo silent corrections or extrapolation to a full-family guaranteed range. Source
03 / PROJECT REVIEW

Evaluate the assembled system and its evidence

Use the entity record without overstating production permission

The original displayed licence identifies the company, credit code and Yangluo site consistently with the preserved CRM export. Its general scope covers refrigeration/air-conditioning equipment manufacture and industrial controls. It also contains wording for special-equipment sales while excluding special-equipment manufacturing from the general manufacture item. Selling or assembling a refrigeration system is therefore not evidence that this company may manufacture every pressure vessel included in it.

For a proposed order, separate the system assembler, compressor maker, pressure-equipment manufacturer and site installer. Ask which components are bought in, which piping/control work is performed by Xinwuxin and which party issues the relevant current documents. Supplier descriptions of fabrication and engineering experience do not replace the exact ordered-unit dossier.

Locate the real equipment boundary

The screw-chiller pages show single/twin-head arrangements, flooded evaporator descriptions and different water or secondary-fluid conditions. The integrated package adds heat-rejection and piping assemblies. The ice machine produces flakes; the container ice system additionally describes a raked storage bin and screw conveying. Parallel racks are compressor packages requiring a selected evaporator/condenser arrangement; they are not complete chilled-water machines by default.

The centrifugal product body describes geared single-stage compression, inlet guide vanes, diffuser control and an emergency oil supply. One earlier website list observation associated its category with the wrong detail URL. The actual body and original drawings, rather than a menu number, determine the product classification here. Model revisions and selected bills of materials still need confirmation.

Make project claims traceable

The company overview attributes equipment supply, refurbishment and engineering work to major concrete-cooling projects, including Baihetan. Its news page presents a Mengdigou procurement-award notice. These are supplier-hosted project statements; the platform has not established an original purchaser-side award record or independently verified performance and acceptance. Customer names and logos are not endorsements of this directory.

Ask for a dated purchaser-approved reference that identifies the supplied scope, actual model, site conditions and acceptance responsibility. For concrete cooling, distinguish cold-water delivery, ice production/storage and aggregate or process cooling. A temperature mentioned in one construction project is not a rated outlet temperature or warranty for all Xinwuxin equipment.

Read government recognition within its date and scope

The Hubei science-and-technology department hosts the 2023 high-tech enterprise list. Its exact-company entry gives certificate GR202342007276 and issue date 8 December 2023. The full PDF and relevant physical page were inspected. This supports a dated enterprise-recognition record; renewal, present issuer status and product-specific conformity were not independently checked.

No blanket current ISO, pressure-vessel, explosion-protection or equipment-performance badge is inferred. The website’s general efficiency and installation-saving percentages have no reviewed test baseline. They should become questions about the selected package, with evidence agreed before procurement.

Separate the industry-directory history and related-company qualifications

A full Refrigeration Market directory profile matches the company name and Yangluo C-F10 location and describes screw-system assembly, refrigeration repair and engineering work. It dates team formation to May 2005, while the original displayed licence and CRM establish the legal registration on 16 March 2005. These are different date boundaries and are not silently reconciled into a new legal establishment date.

The profile attributes installation and pressure-piping qualifications to a closely associated engineering company, without identifying current issuer records for the exact Xinwuxin entity. They are not transferred to this manufacturer. Product recommendations shown elsewhere on the directory page belong to other companies and are not added to Xinwuxin’s catalogue.

Resolve the supplier’s published data inconsistencies

Some screw-chiller footnotes show water inlet/outlet as 5/7°C, while another water-cooled section gives 7/5°C. A section headed water-cooled repeats an evaporative-condenser condition. Several table columns also contain values that do not agree with adjacent power or dimension information. These are explicitly flagged in the relevant product brief instead of silently repaired or copied as guaranteed ratings.

Require a dated selection sheet with refrigerant, fluid composition, inlet/outlet temperatures, heat sink, total electrical input and current model code. Check the approved general arrangement before civil works. The website’s typed email containing a space is retained as raw source text privately; the separate syntactically valid official email is stored in a dedicated CRM field for the later authorised claim process.

  1. Define the process

    Provide the cooling or ice-use profile and the limits at the equipment being cooled.

  2. Close the package boundary

    Identify assembled, bought-in and site-installed components, with named responsible parties.

  3. Approve corrected source data

    Obtain a dated model selection, drawings, documents and agreed acceptance conditions.

07 / TRANSPARENCY

Sources and review scope

Compiled by HVACDeck Editorial. Page review: 2026-10-11. Publications are attributed below; their statements are not independent measurements by this platform.

  1. Official company overviewChecked 2026-10-11 · Full company and process-cooling descriptions read; supplier project/experience claims not independently audited.
  2. Official displayed business licenceChecked 2026-10-11 · Original 1000 × 680 image visually read; legal name, code, date, address and manufacturing-scope limits matched to CRM.
  3. Official contact pageChecked 2026-10-11 · Full address and two email strings read; valid address retained privately without guessing a correction to the malformed string.
  4. Hubei 2023 high-tech enterprise listChecked 2026-10-11 · Complete official PDF downloaded; exact row 7276 on physical page 176 and issue date read, not current-product certification.
  5. Official screw-chiller description and tablesChecked 2026-10-11 · Full body plus all 20 original tables/drawings visually reviewed; inconsistencies explicitly retained.
  6. Official procurement-news pageChecked 2026-10-11 · Full supplier page read; a hosted notice is not independent purchaser-side verification.
  7. Refrigeration Market exact-company directory profileChecked 2026-10-11 · Full profile read; historical formation date distinguished from legal registration; related-company qualifications and third-party recommendations not assigned to Xinwuxin.
  8. Official integrated centrifugal pageChecked 2026-10-11 · Full body, original performance table and dimensional drawing visually reviewed; source conditions, electrical boundaries and mass/dimension anomalies retained.
  9. Official air-cooled screw-chiller pageChecked 2026-10-11 · Full body, two original parameter images and family illustration individually reviewed; missing rating conditions and refrigerant alternatives retained.
  10. Official parallel package description and tablesChecked 2026-10-11 · Entire body and both original parameter images visually reviewed; incompatible narrative/table compressor constructions and incomplete rating conditions preserved.
  11. Official container ice-system pageChecked 2026-10-11 · Complete body, original XIL MS model table and supplier-labelled project collage visually read; missing conditions and dimension/certification boundaries retained.
  12. Official standalone ice-machine pageChecked 2026-10-11 · Reviewed separately to avoid transferring bare-machine ratings and scope to the container system.
  13. Official integrated chiller pageChecked 2026-10-11 · Complete body, original model table and both labelled layout images individually reviewed; drawings are illustrations, not P&IDs or measured tests.

How we review sources · Represent this factory or request a correction