EQUIPMENT / EQUIPMENT FAMILY

HBO air knives · Slot geometry, source pressure and drying acceptance

Compare straight and gate-shaped distribution on one family page, with explicit slot, pressure and process-result boundaries.

From Hunan HBO · Industrial electric hot-air manufacture

Individual product research · HVACDeck Editorial · Sources checked 2026-10-11

HBO air knives · Slot geometry, source pressure and drying acceptance
Manufacturer catalogue image · Air-knife family; straight and gate geometry consolidated
01 / UNDERSTAND THE EQUIPMENT

Specify the air knife together with its air source and workpiece

HBO's standard and gate-shaped air knives are air-distribution components intended to be connected to an external blower, centrifugal fan, compressor or hot-air source. The original standard photograph shows a long plenum with an inlet and bolted slot assembly; the gate image shows a connected top-and-side distribution geometry. They are consolidated here as one air-knife offer rather than counted as separate URLs for repeated straight lengths or geometric variants. The component itself is listed without an electrical-supply requirement; the complete air system still requires a separately selected source.

The standard page describes a 0.5–3 mm adjustable slot and custom lengths of 50–6,000 mm. Its poster states maximum velocity 200 m/s, maximum air-volume range 3–35 m³/min, temperature resistance 200°C and maximum pressure as 5KG. The detailed body separately writes 5 kgf/cm². Those distinctions matter: a resistance statement is not the required working pressure, and a maximum jet speed is not a proven drying result over the entire slot.

02 / READ THE CONDITIONS

Published parameters and their scope

This is an equipment family; its range does not identify one orderable configuration.

Family designation
Air-knife family; straight and gate geometry consolidated

Swipe the table, or focus it and use arrow keys, to read the conditions and sources.

Manufacturer-published values · conditions are part of the specification
ParameterPublished valueConditions and evidence
Disclosed slot and length options0.5–3 mm adjustable slot; 50–6,000 mm custom lengthsOfficial detailed text; exact adjustment method and dimensions need an issued drawing. Source
Published velocity and flowMaximum 200 m/s; 3–35 m³/min maximum-air-volume rangeNo paired selected point, measurement plane or full-slot uniformity test inspected. Source
Published temperature resistance200°CComponent statement; not an automatic limit for all seals, hoses or connected equipment. Source
Pressure-source typographyPoster: 5KG; detailed body: 5 kgf/cm²Retained rather than silently normalised; confirm operating and test pressure for the order. Source
Described body material304 stainless steelSupplier detail text; no inspected material certificate. Source
External air sourceBlower, centrifugal fan or compressor mentionedAir knife has no inherent delivered pressure/heat; source must be separately selected. Source
Geometry scopeStraight, custom and gate-shaped distribution variantsShared family, no artificial URL for each length or shape. Source

Selection and application review

Start with the workpiece and outlet distribution

Provide the workpiece dimensions, conveyor speed, surface condition and required remaining-water or process-result criterion. Select straight or gate-shaped distribution to the actual access and coverage. The gate photograph shows a top-and-side arrangement, but the shared text does not issue a separate verified performance table for that geometry.

Request a dimensioned drawing showing inlet size/location, slot adjustment, mounting points and service access. The 0.5–3 mm and 50–6,000 mm statements are customization ranges, not a catalogue of tested identical results. Keep lengths and shapes as selections within this one offer.

Select the air supply at the knife, not by a maximum headline

The page mentions multiple external sources. Identify which source is actually quoted, its curve and the required condition at the knife inlet after all hoses and fittings. Compressor and blower arrangements cannot be assumed equivalent simply because both appear in the description. Obtain the source's selected operating point and complete electrical input.

The 200 m/s maximum lacks an inspected measurement plane, slot position or reference inlet condition. The maximum volume range is not paired with that maximum speed for every length. Ask for outlet-distribution evidence across the ordered slot and the process stand-off/angle chosen by the responsible designer.

Separate resistance limits from normal operating duty

The parameter poster says 5KG, while the detailed body writes 5 kgf/cm². Obtain the issued allowable working pressure, test pressure and connection ratings for the selected air knife. Do not read a pressure-resistance statement as a recommendation to operate at that pressure, or invent a converted rating from the abbreviated poster.

The 200°C heat-resistance statement also needs to be attached to the exact ordered materials, joints and seals. If paired with a heater whose outlet envelope reaches 350°C, that larger envelope does not override the air knife's stated limit. Confirm the complete connected path's permissible duty using selected documents.

Keep drying and containment claims tied to measured results

The supplier describes water removal after cleaning and a broad range of heated-air applications. It also mentions harmful-gas/dust isolation and sterilization. No inspected capture/containment or microbial validation report was reviewed, so those phrases are not adopted as proof of hazardous-stream isolation, medical sterilization or food-process qualification.

Agree an actual workpiece/result test at the selected speed, inlet air condition and geometry. Record remaining liquid or the relevant measurable acceptance result, together with air-source input and noise where relevant. A jet-speed headline alone cannot establish process throughput or energy savings.

Compare the complete component and source package

Confirm the knife, supply manifold, hoses, source fan/compressor/heater, supports and control scope included in the quotation. Identify air-contact materials and maintenance access; the 304 claim is a supplier statement until the ordered material record is supplied.

Obtain replaceable parts, adjustment instructions and an order-specific warranty. Price, delivery, uniformity, tested drying capacity and independent energy-cost results remain unknown. Repeated standard pictures and custom shapes do not create additional search pages.

  1. Define geometry and result

    Issue workpiece, speed, coverage, inlet/slot and measurable drying acceptance.

  2. Select source and limits

    Match inlet pressure/flow and component temperature/pressure ratings with the whole connection.

  3. Verify the ordered process

    Test distribution and the actual workpiece outcome with complete source energy and noise boundaries.

Sources and review scope

Compiled by HVACDeck Editorial. Source review identifies what the publication states; it is not an independent performance test or certification.

  1. Official HBO standard air knifeChecked 2026-10-11 · Complete product text and original parameter/main illustrations inspected; slot/length options and detailed kgf/cm² wording retained.
  2. Official HBO gate-shaped air knifeChecked 2026-10-11 · Full product body and original gate image read; largely shared limits do not create an independently tested shape rating.

Editorial method and corrections · Report a detail with this page URL

Turn the evidence into an enquiry

Send the manufacturer your required duty, installation conditions and the unresolved items identified in this brief.

Other equipment from this manufacturer

HBO wall-mounted fan heaters · Air distribution and mounting scope

HBO industrial heat guns · Air source and localized thermal duty

HBO hot-air ducts · Insulation, flexibility and connected limits

HBO temperature-control boxes · Sensor, load and protection scope

HBO circulating hot-air packages · Return-air temperature review

HBO portable 3–10 kW hot-air heaters · Supply and process selection