MANUFACTURER PROFILE

Zhengzhou Cling · Vehicle HVAC and thermal management

A Zhengzhou maker of bus heat pumps, roof cooling units and battery thermal-management assemblies, founded in 2003.

Zhengzhou, Henan, China

Prepare a technical enquiry
12 published equipment referencesUpdated 2026-10-11
01 / COMPANY

What this manufacturer offers

郑州科林车用空调有限公司 (Zhengzhou Cling Air Conditioning Co., Ltd.) builds air conditioning and thermal-management equipment for buses and other vehicles. The registration gives 27 September 2003 as the founding date and 8 Changchun Road, Zhengzhou High-tech Development Zone as the address. Cling's company profile says September 2003, its contact page lists the same address, and the legal footer carries the same Chinese name, so the brand and the company match.

The range falls into four groups: electric heat-pump bus air conditioning, traditional bus cooling, integrated passenger and battery thermal systems, and independent battery cooling assemblies. Cling publishes photographs of assembly, brazing and several test laboratories. A January 2025 environmental approval covers a component-process upgrade and a cleaning-wastewater project at the plant, and a November 2025 district-government report lists Cling among newly recognised specialised enterprises. For a quotation, send the vehicle architecture and thermal loads, and ask for the selected model's performance map, current approvals and the production slot for your order.

Legal company
郑州科林车用空调有限公司; registered 27 September 2003The company profile says September 2003; brand and legal footer carry the same name. Source
Address
8 Changchun Road, Zhengzhou High-tech Development Zone, HenanRegistered and published addresses are identical. Confirm it as the site for factory visits and the contract. Source
Published process capability
Assembly, heat-exchanger production, fan production; NOCOLOK brazing, tube expansion and ultrasonic cleaningFrom Cling's strength page and its process photographs. Ask for the line that builds your unit and its throughput. Source
Published test areas
NVH, enthalpy-difference, environmental/vibration and mechanical testingShown in laboratory photographs. Ask for accreditation and calibration records if your project needs them. Source
2025 environmental approval
Component-process technology upgrade and cleaning-wastewater-treatment project; 郑高环审〔2025〕4号, 21 January 2025A conditional project consent. Ask for the later acceptance record if it matters to you. Source
Dated recognition
District report names Cling in the 2025 seventh-batch specialised Little Giant recognitionGovernment article published 11 November 2025; it recognises the company, not individual models. Source
02 / EQUIPMENT

Published equipment and selection data

Cling EFDR independent glycol cooling
series REFERENCE

Cling EFDR independent glycol cooling

Catalogue reference: EFDR-01 / 02 / 03 / 04

Open the equipment selection brief
Parameters and source limits · EFDR-01 / 02 / 03 / 04

Swipe the table, or focus it and use arrow keys, to read conditions and sources.

Manufacturer-published information · EFDR-01 / 02 / 03 / 04
ParameterPublished valueConditions and sources
Cooling sizesEFDR-01/02/03/04: 3/5/8/10 kWAsk for the coolant inlet and outlet, flow and ambient behind each rating. Source
Pump power10 kW and 8 kW pages: 100/240/240/300 W; 3–5 kW page: merged 100 WRequest the pump for your model with its curve; motor watts do not give head. Source
Body sizes on the 10 kW page01: 685 × 600 × 280 mm; 02/03: 818 × 600 × 280 mm; 04: 1,005 × 557 × 280 mmThe 3–5 kW page shows the smaller outline across models; get the drawing for your order. Source
Power supply600 V nominal high voltage; 24 V nominal low voltage; low-voltage demand 450/800/800/1,000 WThe demand row is the low-voltage side; ask for compressor and total input. Source
Coolant, protection and refrigerant50% V/V ethylene glycol; IP67 claim; R134a/R1234yf alternativesAsk for the IP test report, coolant compatibility and which refrigerant is fitted. Source
Options and EMCPTC 5/10/14/24 kW, expansion tank/DC supply options; EN50487:2010 namedOptions are priced separately; ask for the exact EMC standard and report. Source
Cling EDDR roof-mounted liquid battery cooling
series REFERENCE

Cling EDDR roof-mounted liquid battery cooling

Catalogue reference: EDDR-01 / 02 / 03 / 04

Open the equipment selection brief
Parameters and source limits · EDDR-01 / 02 / 03 / 04

Swipe the table, or focus it and use arrow keys, to read conditions and sources.

Manufacturer-published information · EDDR-01 / 02 / 03 / 04
ParameterPublished valueConditions and sources
Cooling modelsEDDR-01/02/03/04: 3/5/8/13 kWAsk for the coolant temperatures, flow and ambient behind each rating. Source
Power supplyHigh 600 V nominal (400–750 V DC); low 24 V nominal (18–32 V DC)Connectors, protection, start-up and DC-DC supply come on the order drawing. Source
Auxiliary power row300/300/600/900 W under an ambiguous low/high-voltage-demand headingAsk what load the row covers. The efficiency figure of 2.2 is printed without a test basis. Source
Coolant and pump50% V/V ethylene-glycol solution; internal pump optionalRequest inhibitor and material compatibility, pump head and pump duty. Source
Outline and connectionsMerged outline 1,300 × 290 × 56 mm; Φ25 connections/custom alternativesThe 56 mm height needs checking on a current drawing for your model. Source
Protection, range and heatingIPX7; cooling operation −20°C to +60°C; optional PTC 5/10/14/24 kWAsk for the dust rating, capacity across the range and which heater goes with which model. Source
Parameters and source limits · DFDD

Swipe the table, or focus it and use arrow keys, to read conditions and sources.

Manufacturer-published information · DFDD
ParameterPublished valueConditions and sources
ApplicationIndependent cooling while parked; airport shuttle and examination-vehicle examplesCling's named uses for the DFDD. Source
DFDD-0637 kW cooling; evaporator 8,000 m³/h; condenser 10,000 m³/h; compressor 650 ccRated at 40°C in the cabin and 35°C outside; speed, humidity and full input to be supplied. Source
Other sizesDFDD-05 33 kW; DFDD-07 44 kWSmaller and larger options in the same family. Source
Roof schemesDD/SDD/BFFD scheme names in the size sectionAsk for the dimensions of the auxiliary unit and the chosen roof combination. Source
AlarmsVoltage, oil pressure and water temperatureRequest trip limits, sensors, sequence and restart logic. Source
Engine and service dataNo engine model, fuel/emissions/noise schedule, refrigerant entry or current installation drawingAll to be supplied with the DFDD selection. Source
Cling FFND/XFND internal bus cooling
series REFERENCE

Cling FFND/XFND internal bus cooling

Catalogue reference: FFND / XFND

Open the equipment selection brief
Parameters and source limits · FFND / XFND

Swipe the table, or focus it and use arrow keys, to read conditions and sources.

Manufacturer-published information · FFND / XFND
ParameterPublished valueConditions and sources
FFND-08 cooling and airflow56 kW; R134a; upper/lower evaporator flow 6,000/3,000 m³/hCling's footnote: 40°C inside, 35°C outside. No humidity or drive speed is given. Source
FFND-08 evaporator sizesUpper 1,468 × 387 × 202 mm; lower 1,510 × 586 × 261 mmTwo separate assemblies. Ask for the installed support and duct envelope of each. Source
FFND-06 condenser optionsSide 855 × 476 × 1,085 mm; rear 1,951 × 372 × 443 mmTwo mounting choices for one model; ask Cling which drawing applies to your order. Source
XFND-10 condenser size588 × 20 × 702 mm as printedThe 20 mm depth is unusual for a condenser. Ask Cling for the correct dimension on a current drawing. Source
Compressor displacementFFND-08 750 cc; FFND-06 650 cc; all models R134aThe compressor model, drive and line sizing come with the selection. Source
Data to requestRefrigerant line lengths and charge, electrical input and current, control and pressure scheduleThe family table lists capacity, airflow and sizes only. Source
Cling GZHD/EZHS rear-mounted bus HVAC
series REFERENCE

Cling GZHD/EZHS rear-mounted bus HVAC

Catalogue reference: GZHD / EZHS

Open the equipment selection brief
Parameters and source limits · GZHD / EZHS

Swipe the table, or focus it and use arrow keys, to read conditions and sources.

Manufacturer-published information · GZHD / EZHS
ParameterPublished valueConditions and sources
GZHD-08 cooling56 kW; R134a; 830 cc compressor displacementGZHD rows list cooling only. Source
EZHS-08 cooling and heating60 kW cooling; 58 kW heating; R410AAsk for the heating conditions and the electrical platform with the selection. Source
Rear body sizesGZHD-08: 2,000 × 750 × 1,230 mm; EZHS-08: 2,000 × 750 × 1,167 mmSame footprint, different heights. Supports and service space come from the installation drawing. Source
AirflowEvaporator 10,000 m³/h on both large models; condenser GZHD-08 12,000 / EZHS-08 14,000 m³/hCatalogue flows; external pressure is not stated. Source
Current entriesGZHD-08 85 A; EZHS-08 103 A under a maximum-power headingSupply voltage is not given, so these figures cannot be turned into watts. Source
Air distributionBalanced upper and lower air supplyCling's description; ask for the zone split at your duct resistance. Source
Cling CM160 narrow-body Jeepney cooling
series REFERENCE

Cling CM160 narrow-body Jeepney cooling

Catalogue reference: CM160 / CM160S

Open the equipment selection brief
Parameters and source limits · CM160 / CM160S

Swipe the table, or focus it and use arrow keys, to read conditions and sources.

Manufacturer-published information · CM160 / CM160S
ParameterPublished valueConditions and sources
CM160 bodyCM160: 2,200 × 1,360 × 210 mm; 90 kgAsk for the mounting frame and support envelope on the installation drawing. Source
CM160S16 kW; 96 kg; 2,200 × 1,360 × 215 mmThe higher-output version in the same family. Source
CM160 cooling14 kW; R134aRequest the air temperature, humidity and compressor speed behind the rating. Source
Airflow and compressorEvaporator 3,200 m³/h; condenser 4,000 m³/h; 313 cc compressorShared by both versions; ask for delivered airflow after ducting. Source
Electrical row55 A beneath maximum-power headingPrinted without a voltage; ask what load the 55 A covers. Source
Weight comparisonSource compares 90 kg unit with a previous 139 kg productAsk for the cooling duty of the older product to compare like with like. Source
Parameters and source limits · XDD

Swipe the table, or focus it and use arrow keys, to read conditions and sources.

Manufacturer-published information · XDD
ParameterPublished valueConditions and sources
XDD-03 cooling and air23 kW; R134a; evaporator 4,000 m³/h; condenser 5,400 m³/hFootnote conditions: indoor 40°C, outdoor 35°C. Humidity and compressor speed are left blank. Source
Compressor optionsXDD-03 displacement 380/430 ccTwo compressor sizes; each needs its own selection and drive. Source
Roof unit2,752 × 1,848 × 220 mm; 140 kgSuggested for 8–10 m buses. Roof structure is checked by the body builder. Source
Electrical columnXDD-03 under a maximum-power heading: 65 AAmperes, not watts; supply voltage and full demand are not given. Source
Other sizesXDD-02 19 kW; XDD-04T 28 kWSame family and rating footnote. Source
EMC statementNational-standard level IICling names no standard number, version or report; ask for them. Source
Cling DD traditional roof bus cooling
series REFERENCE

Cling DD traditional roof bus cooling

Catalogue reference: DD / CM350 / BFFD reference

Open the equipment selection brief
Parameters and source limits · DD / CM350 / BFFD reference

Swipe the table, or focus it and use arrow keys, to read conditions and sources.

Manufacturer-published information · DD / CM350 / BFFD reference
ParameterPublished valueConditions and sources
DD-06 cooling37 kW; R134a; 647 cc compressor displacementTest footnote gives a 40°C cabin and 35°C ambient; ask for the humidity and compressor speed. Source
DD-06 roof unit and air180 kg; 3,380 × 1,840 × 210 mm; evaporator 6,000 m³/hMounting details and delivered duct flow come with the selection. Source
Electrical columnHeaded maximum power; DD-06 value 90 AAmperes without a voltage; ask for the supply and full electrical and shaft demand. Source
CM350 comparison37 kW; 647 cc; 170 kg; 3,350 × 1,720 × 250 mm; 95 ASeparate Cling table with the same air-temperature footnote. Source
BFFD construction optionCopper-tube and aluminium-fin coils; BFFD-06 37 kW, 255 kgWidth figures vary oddly across the BFFD table; ask for the current drawing. Source
DD featuresLighter weight, faster maintenance and high-efficiency PM2.5 filtrationCling's description of the DD range; ask for the data behind each point. Source
Parameters and source limits · CEZDD

Swipe the table, or focus it and use arrow keys, to read conditions and sources.

Manufacturer-published information · CEZDD
ParameterPublished valueConditions and sources
RefrigerantR744 (CO₂)Ask for the charge and the full pressure envelope of the ordered unit. Source
CEZDD-0430 kW cooling; 34 kW heating; evaporator 6,000 m³/h; compressor displacement 7.3 m³/hDisplacement is a swept volume; ask separately for electrical input. Source
CEZDD-0633 kW cooling; 37 kW heating; compressor displacement 10.9 m³/hLarger size in the same family. Source
Ambient range−30°C to 45°C ambient operationRequest heating, input and defrost figures near both limits. Source
DimensionsCEZDD-04: 3,250 × 2,000 × 345 mm; CEZDD-06 length 3,500 mmWeight, supports and service envelope come on the installation drawing. Source
Pressure and efficiencyRelief valve plus pressure control; about 30% heating-COP improvement at −10°CAsk for the relief settings and the system the COP is compared against. Source
Parameters and source limits · EZDD / EZDS

Swipe the table, or focus it and use arrow keys, to read conditions and sources.

Manufacturer-published information · EZDD / EZDS
ParameterPublished valueConditions and sources
Electrical supplyHigh voltage 400–750 V; low voltage 24 VFrom the family table; ask for current, start-up and protection limits. Source
EZDS-04 output28 kW cooling; 26 kW heatingRated with 40°C indoor and 35°C outdoor; Cling should state the heating and humidity conditions. Source
RefrigerantR407CDifferent from the R410A LEZDS-J and the R744 CEZDD; request charge and service data. Source
EZDS-04 airflow and bodyEvaporator 4,000 m³/h; condenser 8,000 m³/h; 2,750 × 2,000 × 260 mm; 245 kgAgree air distribution and roof supports with the body builder. Source
ProtectionKey components described as IP67Ask for the component list and test report, and the rating of the complete unit. Source
Battery coolingNo battery coolant-capacity row in this ordinary family tableBattery duty is quoted on the integrated J-series units. Source
Parameters and source limits · EZDD-J / EZDS-J

Swipe the table, or focus it and use arrow keys, to read conditions and sources.

Manufacturer-published information · EZDD-J / EZDS-J
ParameterPublished valueConditions and sources
ArchitectureRoof passenger HVAC plus liquid-battery thermal managementAsk for the order P&ID showing the coolant equipment and valves. Source
EZDS-04-J28 kW passenger cooling; 26 kW heating; battery 5/8 kW driving/chargingTable footnote sets 40°C inside, 35°C outside. Battery and heating conditions are missing; request them. Source
EZDD-04-JEZDD-04-J: 17 kW cooling, 16 kW heating, battery 3/5 kWEach model has its own battery row. Source
Refrigerant and airflowR407C; EZDS-04-J evaporator 4,000 m³/h, condenser 8,000 m³/hRequest charge, motor input and air-distribution interfaces. Source
EZDS-04-J bodyEZDS-04-J: 2,750 × 2,000 × 260 mm; 255 kgListed for a 7.5–9 m bus; roof loads need the body builder's approval. Source
Cost and weight claims30% lower overall cost and 20% lower vehicle weight advertisedAsk Cling what separate system the figures compare against. Source
Parameters and source limits · LEZDS-J

Swipe the table, or focus it and use arrow keys, to read conditions and sources.

Manufacturer-published information · LEZDS-J
ParameterPublished valueConditions and sources
Models and refrigerantLEZDS-04-J / LEZDS-06-J; R410ADifferent refrigerant from the R407C and R744 Cling families. Source
LEZDS-04-J28 kW cooling; 25 kW heating; 4,000 m³/h evaporator airflowRating point 40°C indoor / 35°C outdoor; request heating, humidity and voltage conditions. Source
Battery cooling5/8 kW for both published modelsDriving / charging. Request coolant temperatures, flow and a combined-load map. Source
LEZDS-04-J bodyLEZDS-04-J: 2,750 × 2,000 × 260 mm; 260 kg; suggested 8–9 m busRoof loads, mounting and service space need the vehicle builder's approval. Source
Climate and energyAmbient −15°C to 50°C; over 50% less power than traditional PTC promotedAsk for output at your low point and the PTC comparison basis. Source
LEZDS-06-JLEZDS-06-J: 38 kW cooling, 34 kW heating; 315 kg; 3,250 × 2,000 × 260 mmUse the current selected schedule for the order. Source
03 / ORDERING

Zhengzhou Cling: bus HVAC, battery cooling and how to order

Passenger cooling, heat pumps and battery loads

Cling's catalogue covers electric passenger heat pumps such as the EZDD and EZDS units, traditional roof cooling and battery thermal management. Some passenger assemblies include a battery circuit. Others list only passenger air-side duties. Select against the exact vehicle architecture, because liquid battery cooling comes only with the models built for it, such as the EDDR battery cooling unit.

Send Cling the cabin sensible and latent load, the door and occupancy profile, battery heat rejection while driving and while charging, the available voltages and the ambient range. Say whether the quote should cover the roof unit alone, the full refrigerant circuit, battery coolant equipment, controls or installation. The vehicle length printed in the catalogue is a suggested fit range; the heat-load calculation for your bus comes from the selection.

Factory processes and test laboratories

Cling's strength page describes automated assembly, heat-exchanger and fan lines. The photographs show assembly equipment and a brazing area, plus an acoustic room, test cabinets and mechanical test rigs. Ask for the manufacturing route of the ordered heat exchanger, the refrigerant joints, the electrical components and the finished assembly.

For qualification, request material and component traceability, joining and leak-test controls and end-of-line checks. Add the model-specific thermal, vibration, EMC and acoustic test reports your vehicle project requires, with the standard each one follows and the laboratory's accreditation where needed.

The January 2025 environmental approval

The approval, hosted by the district government, names the same legal company. It covers a component-process upgrade and a cleaning-wastewater-treatment station. Its conditions set out process exhaust treatment, wastewater handling, noise, waste and later environmental acceptance and monitoring.

The document records a disclosed manufacturing project and the conditions attached to it. If supplier qualification depends on that project, ask Cling for the completed acceptance and current operating records. Refrigeration performance and vehicle type approval need their own documents.

Certificates, capacity figures and service

Cling's profile states TS 16949 and E-MARK, and its promotional pages report production capacity, patents and export reach. The installed-unit and patent counters on the home page and the profile give different totals. Ask Cling for one dated figure for each, and for the holder, scope, model and validity of every certificate you rely on.

The November 2025 district report names Cling among three newly recognised specialised enterprises. That recognition applies to the company; model approvals come separately. Delivery and warranty banners on the website are general. Get a written warranty and service agreement for your destination.

Building the vehicle purchase file

Give Cling the duty and climate inputs, vehicle and roof drawings, the electrical architecture, battery coolant requirements and the conformity rules of the destination market. In return, ask for the selected model and configuration, a current performance map at stated conditions, interfaces and controls, mounting and service requirements and an acceptance plan.

Agree how thermal performance will be checked at idle, while driving and while charging, along with vehicle controls, leak and electrical checks and any road or environmental validation the project requires.

  1. Define all thermal loads

    Separate cabin, battery, driving and charging requirements before asking for a model.

  2. Qualify the manufacture and approvals

    Obtain process controls, current certificate scope and model test reports.

  3. Approve vehicle integration

    Close power, controls, mounting, service access and acceptance tests.

Confirm in writing before ordering from Cling

Ask Cling to state in the offer: which model and configuration you are buying and whether it includes battery cooling; its performance at your ambient and charging conditions; the plant and line that build it; current TS 16949 and E-MARK certificates naming the model; the test reports and acceptance checks you will receive; lead time, stock position and the warranty and service terms for your country.

07 / SOURCES

Sources

Compiled by HVACDeck Editorial. Updated 2026-11-06. Each fact on this page comes from the publication listed below.

  1. Official Cling company profileChecked 2026-10-11 · Company history, founding date, certificates and scale figures.
  2. Official contact pageChecked 2026-10-11 · Company address in Zhengzhou High-tech Development Zone.
  3. Official strength and process pageChecked 2026-10-11 · Production lines, brazing and cleaning processes, and photographs of assembly and test laboratories.
  4. Government environmental approval with attachmentChecked 2026-10-11 · Conditional approval of 21 January 2025 for the component-process upgrade and wastewater project, with its conditions.
  5. Zhengzhou High-tech government recognition reportChecked 2026-10-11 · Article of 11 November 2025 naming Cling among three recognised specialised enterprises.
  6. Official 10 kW capacity pageChecked 2026-10-11 · Series table with pump powers and body sizes by model.
  7. Official 8 kW capacity pageChecked 2026-10-11 · Series table used to compare pump and body entries.
  8. Official 3–5 kW capacity pageChecked 2026-10-11 · Series table with merged pump and outline cells.
  9. EFDR unit photographChecked 2026-10-11 · Shows the fan and connection side of the unit.
  10. Official EDDR roof liquid-cooling series pageChecked 2026-10-11 · Four-model table with voltages, coolant, pump option, outline, protection and the configuration update notice.
  11. Official 8 kW capacity pageChecked 2026-10-11 · Repeats the four-model series table.
  12. Official 13 kW capacity pageChecked 2026-10-11 · Repeats the series table without separate coolant conditions.
  13. EDDR roof unit photographChecked 2026-10-11 · Shows the roof unit's appearance.
  14. Official DFDD independent-drive pageChecked 2026-10-11 · Three-model table, parked-use description, alarm and engine statements and the configuration update notice.
  15. DFDD auxiliary assembly imageChecked 2026-10-11 · Photograph of the engine and compressor package.
  16. Official internal-family product pageChecked 2026-10-11 · Four-model table with capacity, airflow, compressor displacement and separate condenser and evaporator dimensions, plus the zoning and construction features.
  17. Cling product imageChecked 2026-10-11 · Photograph of the fan and exchanger assembly used for the internal family.
  18. Official GZHD/EZHS rear-family pageChecked 2026-10-11 · Combined table for both architectures with cooling, heating, airflow, current and sizes, the balanced-air description, the rating footnote and Cling's configuration notice.
  19. Cling rear-family photographChecked 2026-10-11 · Photograph of the fan-bank assembly used for the rear family.
  20. Official CM160/CM160S pageChecked 2026-10-11 · Two-model table, Jeepney and PUV application, weight comparison and the configuration update notice.
  21. CM160 family imageChecked 2026-10-11 · Photograph of the compact roof unit.
  22. Official XDD school-bus pageChecked 2026-10-11 · Three-model table with cooling, airflow, compressor options, mass, size and current, plus the microchannel, fan-control and EMC statements.
  23. Cling XDD family imageChecked 2026-10-11 · Photograph of the yellow school-bus roof unit.
  24. Official DD family pageChecked 2026-10-11 · Six-model table with cooling, airflow, displacement, mass, sizes and current, the rating footnote and Cling's feature list.
  25. Cling DD family imageChecked 2026-10-11 · Photograph of the DD roof unit family.
  26. Official CM350 product pageChecked 2026-10-11 · Single-model schedule with cooling, displacement, size, mass and current, used for the DD-06 comparison.
  27. Official BFFD product pageChecked 2026-10-11 · BFFD table and construction notes on copper-tube and aluminium-fin coils and fan speed control.
  28. Official CEZDD R744 pageChecked 2026-10-11 · Two-model table with climate range, COP, protection statements and the configuration update notice.
  29. CEZDD family imageChecked 2026-10-11 · Photograph of the roof unit family.
  30. Official EZDD/EZDS pageChecked 2026-10-11 · Five-model table, electrical platforms, the IP67 component statement and the configuration update notice.
  31. EZDD/EZDS family imageChecked 2026-10-11 · Photograph of the roof unit; ask for motor, electrical and control details.
  32. Official integrated J-series pageChecked 2026-10-11 · Five-model table with cabin and battery rows, integration description, test footnote and update notice.
  33. Integrated family imageChecked 2026-10-11 · Photograph of the roof unit; circuit contents come with the order documents.
  34. Official LEZDS-J pageChecked 2026-10-11 · Two-model table, test footnote, climate range, PTC energy statement and the configuration update notice.
  35. LEZDS-J family imageChecked 2026-10-11 · Photograph of the roof unit; plumbing and electrical scope come with the order.

How we compile profiles · Represent this factory or request a correction

Prepare your equipment brief